Mikrochimica acta

A pair of inverse ratiometric sensing paradigms based on stimulus response of AIE@ZIFs via solvent-assisted aggregation-induced emission modulation and substituent-dependent ligand emission regulation for dynamic monitoring of PFAS-induced ATP changes in cardiomyocytes.

Yiwen Min, Ziyang Ge, Chunqian Yu, Shu Zhang, Chenyi Xue, Ying Zhang, Tianshu Zhou, Wanying Zhai,

Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, School of Ecological and Environmental Sciences, 500 Dongchuan Road, Shanghai, 200241, China. · Changjiang Basin Ecology and Environment Monitoring and Scientific Research Center, Ministry of Ecology and Environment, 13 Yongqing Road, Wuhan, 430019, China. zhaiwanying@cjjg.mee.gov.cn.

Key points

From the paper's conclusion
  • Based on ATP-triggered responses, we developed inverse ratiometric sensing paradigms through solvent-assisted AIE modulation and substituent-dependent LE regulation, which have been rarely explored.

Abstract

Two aggregation-induced emission (AIE) guests, tetra[4-(3,5-dicarboxyphenyl)] tetraphenylethylene (H8ETTB) and dispersed Cu nanoclusters (D-CuNCs), were separately encapsulated into ZIF-8 and ZIF-90, which bear methyl-substituted and aldehyde-functionalized imidazole ligands, respectively. The constructed AIE@ZIFs (H8ETTB@ZIF-8 and A-CuNCs@ZIF-90) integrate dual emissions from the guests and the intrinsic ligand emission (LE) of the ZIF skeletons. Based on ATP-triggered responses, we developed inverse ratiometric sensing paradigms through solvent-assisted AIE modulation and substituent-dependent LE regulation, which have been rarely explored. The distinct fluorescence color changes (bluish-green to green; orange-red to blue), arising from opposite emission responses of the guests and ligands, enable reliable color-oriented analysis. H8ETTB@ZIF-8 affords a linear range of 0.02-6 mM ATP with detection limits of 9.84 µM (spectral) and 19.86 µM (smartphone), while A-CuNCs@ZIF-90 exhibits a linear range of 0.01-3 mM with limits of 4.26 µM and 8.52 µM, respectively. Both nanoprobes show outstanding anti-interference performance and can be internalized into cardiomyocytes (H9c2) for in situ imaging of ATP dynamics and accurate quantification of PFAS-induced ATP perturbations. Mitochondrial ATP loss is validated as an appropriate cardiotoxicity indicator for PFOS and PFOA, thereby advancing the toxicological assessment of emerging pollutants.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers