Large-Scale Testing for Characterisation of Cable Bolt System Behaviour: A Novel Laboratory Approach to Simulate Relative Joint Shear Sliding
Sriskanthan Srisangeerthanan, Danqi Li, Javad Hashemi, Hossein Masoumi
Key points
From the paper's conclusion- These results highlight the combined effects of pre-tensioning, grout, anchorage and lateral restraint on system behaviour, and in overall, the study establishes the versatility of the MAST facility in accommodating shear testing of cable bolt systems.
Abstract
This study investigates the performance of a cable bolt system under direct shearing to simulate relative rock strata under horizontal or so called “sliding”, with the primary goal of assisting in the optimisation of cable bolting practice to control roof failure in underground excavations. The multi axis substructure testing (MAST) facility was employed to develop a novel large-scale testing system. A widely used locally sourced cable bolt was selected with various testing conditions concerning the absence or presence of anchorage, grouting and cable bolt pre-tensioning, including lateral restraint to the embedment. The study shows that pre-tensioning can enhance early-stage stiffness, particularly when a lateral restraint is applied to the embedment, but its effect diminishes at larger displacements due to grout fracturing, cable bolt sandwiching, cable bolt yielding and the cracking of the reinforced concrete embedment. Grouting was essential for proper load transfer and to eliminate excessive sliding, which has been seen in the un-grouted case, where with grouted systems, failure was predominantly associated with the joint interface cracks than any bond related failures. End anchorage had limited influence, where both anchored and un-anchored systems converged in stiffness at initial cracking, although, at larger displacements, un-anchored systems seemed to be more prone to the effects of slippage. Lateral restraint mitigated cantilever-action induced rotation and un-desired localised embedment interaction, although its impact on overall stiffness was mixed. These results highlight the combined effects of pre-tensioning, grout, anchorage and lateral restraint on system behaviour, and in overall, the study establishes the versatility of the MAST facility in accommodating shear testing of cable bolt systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bond Stress Distribution at the Joint Between Rock Bolts and Grout Under Different Grouting Conditions.Materials (Basel, Switzerland) · 2026
- Instability Characteristics and Active Control of Jointed Surrounding Rock in Super-Large-Span Shallow-Buried TunnelsEngineering Research Express · 2026
- Experimental study on the structural failure characteristics and load-bearing mechanism of anchored fractured rock massScientific Reports · 2026
- Mechanical Response and Failure Mechanisms of Cable-Bolt Reinforcement Under Impact Loading.Materials (Basel, Switzerland) · 2026
- Time differential development of destruction mechanism of bolt anchorage system in composite rock formationGeomechanics and Geophysics for Geo-Energy and Geo-Resources · 2025
- Impact of installation variations on axial performance of rock bolts: an experimental and numerical studyGeomechanics and Geophysics for Geo-Energy and Geo-Resources · 2026