Artificial intelligence (AI) in implant selection: an evaluation of AI-generated preoperative templating in total joint arthroplasty.
Catherine Call, Mohammad Daher, Jonathan Liu, Phillip Schmitt, Jeffrey Okewunmi, Sydney Rozenfeld, Janine Molino, Valentin Antoci,
Brown University, Providence, USA. · Brown University, Providence, USA. mohdaher1@hotmail.com.
Key points
From the paper's conclusion- AI-generated TJA templating software appears to overestimate component sizing and for THA templating does not outperform surgeons in evaluated metrics. While such technology shows promise in aiding in the preoperative templating workflow, refinement is necessary before integration into clinical practice.
Abstract
AIMS: Artificial intelligence (AI) applications have become widely accessible resources, and the race is on to determine the safe application of this technology within total joint arthroplasty (TJA). One area of investigation is the use of AI with in preoperative templating for total hip (THA) and total knee arthroplasty (TKA). This study aimed to compare the accordance of AI- and surgeon-generated templates to the implants utilized in consecutive TJA cases. METHODS: A retrospective review was performed of 349 THA and 390 TKA cases from a single academic arthroplasty practice between March 2025 and October 2025. Preoperative radiographs were evaluated to produce AI- and surgeon-generated THA templates for cup and stem size, which were compared to components implanted. For TKA, AI-generated template was compared to implanted femoral, tibial, and patellar components. Analysis was performed using mixed-effects models with a random intercept for surgeons, with Holm-adjusted two-tailed significance set at α = 0.05. RESULTS: For THA, surgeon and AI-generated templates overestimated cup (p < 0.0001) and stem (p < 0.0001) size. Surgeon-templated stem sizes were utilized in 30.1% of cases, making surgeon more frequently accurate than AI (22.4%; p = 0.02). Surgeon and AI-templated cup sizes were utilized in 35.8% and 29.8% of cases, respectively, which was not a statistically significant difference (p = 0.09). Compared with the actual implants utilized in TKA, AI tended to oversize femoral, tibial, and patella components. Artificial intelligence templating predicted implanted femoral and tibial size within two sizes in 85.9% and 84.4% of cases, respectfully, and predicted patella size within three millimeters in 92.6% of cases. CONCLUSION: AI-generated TJA templating software appears to overestimate component sizing and for THA templating does not outperform surgeons in evaluated metrics. While such technology shows promise in aiding in the preoperative templating workflow, refinement is necessary before integration into clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artificial intelligence-based versus conventional preoperative templating for tibial and femoral component size estimation in total knee arthroplasty: a systematic review and meta-analysis.The Knee · 2026
- Comparison of artificial intelligence-assisted or CT-based 3-dimensional preoperative planning with conventional 2-dimensional templating in total hip arthroplasty.Medicine · 2026
- Artificial Intelligence-Based Three-Dimensional Preoperative Planning for Total Knee Arthroplasty in End-Stage Knee Osteoarthritis.Journal of visualized experiments : JoVE · 2026
- Artificial Intelligence in Total Hip and Knee Arthroplasty: A Primer on Current Applications, Algorithms, and Future DirectionsJBJS Reviews · 2026
- AI-powered preoperative planning combined with robotic-assisted execution in total knee arthroplasty: A propensity score-matched analysis of prosthesis sizing accuracy, perioperative outcomes, and early functional recovery.Journal of orthopaedic surgery (Hong Kong) · 2026
- Artificial intelligence in total knee arthroplasty: clinical applications and implicationsKnee Surgery and Related Research · 2025