Syndesmotic screw fixation is associated with higher overall treatment costs when compared with suture button stabilisation in a single UK major trauma centre.
Hafiz Muhammad Umer, Aima Gilani, Khadija Aman, Edward Gee
Department of Trauma & Orthopaedics, Salford Royal Hospital, Manchester, UK. umer805@hotmail.com. · Department of Trauma & Orthopaedics, Salford Royal Hospital, Manchester, UK.
Key points
From the paper's conclusion- Despite a higher initial implant cost, suture button stabilisation demonstrated fewer complications and no hardware removals. In contrast, 56.8% of screw fixation cases underwent implant removal, leading to screw fixation costing £687 more per case on average, highlighting the superior clinical and economic value of suture button stabilisation in this pragmatic study.
Abstract
BACKGROUND: Ankle fractures frequently involve syndesmotic disruption, requiring stable fixation to restore joint function. Syndesmotic screw fixation remains widely used but carries significant drawbacks, including implant breakage, stiffness, and frequent need for removal. Suture button stabilisation offers clinical and economic advantages by preserving physiological motion and reducing reoperation rates. This study evaluates these costs under normal, unselected clinical practice, where implant choice and removal decisions were made independently by treating surgeons without protocol influence. METHODS: This retrospective cohort study compares treatment costs of syndesmosis screw fixation and suture button stabilisation for syndesmotic injuries in a single UK Major Trauma Centre. 75 patients aged 16-60 years, with length stable or length stabilised ankle fractures with syndesmotic injuries, between October 2020 to October 2023 were included. RESULTS: The two cohorts were demographically similar and operative times were comparable (p = 0.170). Complications and reoperations were significantly higher with screw fixation (p < 0.001), with 56.8% undergoing removal, adding £31,460 in costs over three years. Overall, screw fixation cost £687 more per case than suture button stabilisation. Screw fixation became more costly when the hardware removal rate exceeded 8%. This dropped further to 2% when costs of additional follow up visits were also included. CONCLUSION: Despite a higher initial implant cost, suture button stabilisation demonstrated fewer complications and no hardware removals. In contrast, 56.8% of screw fixation cases underwent implant removal, leading to screw fixation costing £687 more per case on average, highlighting the superior clinical and economic value of suture button stabilisation in this pragmatic study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of screw and suture-button techniques in the treatment of ankle syndesmotic injuries.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2026
- Long-term outcomes of suture button vs syndesmotic screw fixation for ankle syndesmotic injuries: A systematic review and meta-analysis of randomized controlled trials.Foot (Edinburgh, Scotland) · 2026
- Suture-Button Fixation Provides a Statistically But Not Clinically Important Improvement in Function for Syndesmotic Injuries in Unstable Ankle Fractures: A Systematic Review and Network Meta-Analysis of Randomized Controlled Trials.JB & JS open access · 2026
- Suture button versus syndesmotic screw fixation in acute ankle fractures with syndesmotic injury: An umbrella review of functional outcomes and clinical relevance based on the minimal clinically important differenceInjury · 2026
- No benefit of routine syndesmotic screw removal and increased risk of complications: A retrospective analysis of 146 patients, minimum 2 years follow-up.SICOT-J · 2026
- AO type C ankle fractures with additional posterior malleolus fragment: radiological and functional results of osseous reconstruction of the tibiofibular syndesmosis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026