Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.
Michael Coons, Fiona Cherry, Sophia Miller, Nina Fisher, Kenneth Egol
New York University Langone Orthopedic Hospital, New York, USA. · New York University Langone Orthopedic Hospital, New York, USA. kenneth.egol@nyulangone.org.
Key points
From the paper's conclusion- Smart Crutch Tips™ significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.
Abstract
PURPOSE: To evaluate the effectiveness of Smart Crutch Tips™ in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n = 10) used Smart Crutch Tips™ (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n = 10) also used crutches equipped with Smart Crutch Tips™, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within ± 10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p < 0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips™ significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Smart Device Development for Gait Monitoring: Multimodal Feedback in an Interactive Foot Orthosis, Walking Aid, and Mobile ApplicationTechnologies · 2025
- DESIGN REFINEMENT AND TAKE-HOME TESTING OF A MOBILE MANUAL STANDING WHEELCHAIR.Proceedings of the ... Design of Medical Devices Conference. Design of Medical Devices Conference · 2026
- Test-Retest Reliability of the Power-Mobility Indoor Driving Assessment for Older Adults.Canadian journal of occupational therapy. Revue canadienne d'ergotherapie · 2026
- User preference-based human-in-the-loop tuning of exoskeleton assistance during walkingnpj Biomedical Innovations. · 2026
- Design and Evaluation of FALL-E: A Robotic Rollator for Studying Balance Response to Overground PerturbationACM Transactions on Human-Robot Interaction · 2026
- The impact of power assist devices on manual wheelchair use across international classification of functioning, disability and health framework categories and the implications for insurance policy coverage: A scoping review.Assistive technology : the official journal of RESNA · 2026