Digital twin validation and predictive value of delta radiomics based on tabular transformer for synergistic muscle imbalance in lumbar disc degeneration.
Baichuan Mu, Zhe Fan, Yinzhong Chen, Jingguo Wu
School of Sports Medicine and Rehabilitation, Shandong First Medical University, Tai'an, China. · Department of Joint Surgery, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, China.
Key points
From the paper's conclusion- Delta radiomics can sensitively capture microscopic muscle imbalance. Combined with the nonlinear modeling advantages of the Tabular Transformer architecture, this approach provides an objective, interpretable, and quantitative basis for the early non-invasive diagnosis and risk stratification of LIDD.
Abstract
BACKGROUND: Current methods struggle to quantify muscle synergistic imbalance and nonlinear interactions in Lumbar Intervertebral Disc Degeneration (LIDD). This study proposes a novel strategy combining "Delta Radiomics" with a Tabular Transformer deep learning architecture, aiming to improve the precision of early risk assessment. METHODS: A retrospective analysis was conducted on L4-L5 MRI images from 663 subjects. Texture features of the Psoas Major (PM) and Erector Spinae (ES) were extracted, and (PM-ES)/ES was calculated as the "Delta Feature" to eliminate individual variation. An in silico digital twin simulation system was constructed to validate the physical sensitivity of these features. The predictive performance of the nonlinear Tabular Transformer model was compared with a traditional logistic regression model. RESULTS: In silico experiments confirmed that Delta features possess superior "common-mode noise rejection" capabilities. In the early stage of degeneration (Step 20), when original features showed only weak changes, Delta features detected highly significant inter-group differences (P < 0.001). In the independent test set, the Tabular Transformer model demonstrated the best discriminative power with an AUC of 0.848 (95% CI: 0.781-0.916), outperforming the Combined linear model utilizing the same features (AUC = 0.804, P = 0.089) and single-modality models. Although the raw AUC improvement was marginal, Decision Curve Analysis (DCA) and quantitative calibration (Brier score = 0.145) showed that the Transformer model offered higher net clinical benefit and superior absolute risk estimation across a wider threshold range. Additionally, SHAP analysis revealed that the core features identified by the model highly aligned with the biomechanical compensation failure mechanisms set in the simulation, validating the model's decision logic. CONCLUSION: Delta radiomics can sensitively capture microscopic muscle imbalance. Combined with the nonlinear modeling advantages of the Tabular Transformer architecture, this approach provides an objective, interpretable, and quantitative basis for the early non-invasive diagnosis and risk stratification of LIDD.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A machine learning model integrating radiomics and clinical factors to predict recurrence risk after rehabilitation in lumbar disc herniation.Medicine · 2026
- Magnetic Resonance Imaging-Based Radiomics for Quantitative Assessment of Cervical Disc Degeneration: A Dual-Cohort Study.Neurospine · 2026
- Identification of AHR, UACA, GCLM, and GSTZ1 as candidate genes associated with metabolic alterations in intervertebral disc degenerationScientific Reports · 2026
- Combining MRI dual-sequence radiomics and clinical parameters predicts post-hypertriglyceridemic acute pancreatitis diabetes mellitus.Frontiers in endocrinology · 2026
- A Multi-Structural Radiomic Digital Phenotyping Framework for Deciphering Preclinical Evolution of Degenerative Meniscal Tears.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Radiomics in spinal research: a narrative review.Frontiers in bioengineering and biotechnology · 2026