Clinical outcomes and complications of the posterior dynamic distraction device in adolescent idiopathic scoliosis: a systematic review and meta-analysis.
Chuck H Lam, Alma Sato, Halil Ibrahim Bulut, Jonathan Gibson, Conor T Boylan, Jwalant S Mehta, Morgan Jones
Cedars-Sinai Spine, Cedars-Sinai Medical Center, Los Angeles, United States. chuck.lam2@nhs.net. · Medical School, University of Nicosia, Nicosia, Cyprus.
Key points
From the paper's conclusion- PDDD provides moderate short-term curve correction, but approximately one in four patients experiences a complication and nearly one in three requires reoperation at short-term follow-up. Reported perioperative advantages derive from only two to three uncontrolled cohorts. PDDD does not yet match PSF for reliability or percentage correction, nor VBT for reoperation rates. Pending larger comparative studies with long-term follow-up, PDDD should be considered investigational and patients counselled accordingly.
Abstract
PURPOSE: The posterior dynamic distraction device (PDDD) is a fusionless implant for adolescent idiopathic scoliosis (AIS). We aimed to quantify pooled major-curve Cobb correction, complication, revision, and infection rates after primary PDDD implantation for Lenke 1 or 5 curves, and to place these outcomes in context alongside posterior spinal fusion (PSF) and vertebral body tethering (VBT). METHODS: Following PRISMA guidance (PROSPERO: CRD420251074442), PubMed, Embase, Scopus, and Web of Science were searched to May 2025. Random-effects meta-analyses were performed for Cobb correction, complications, and revisions, with leave-one-out sensitivity analyses. RESULTS: Five studies (148 unique patients; mean age 13.1-16.0 years) met the inclusion criteria. Pooled mean Cobb correction was 22.8° (95% CI: 14.2-31.4°), approximately 51% of the preoperative magnitude; however, heterogeneity was extreme (I²=98%; prediction interval - 14.5° to 60.1°), and this pooled figure should not be interpreted as a reliable estimate of expected correction. The pooled complication rate was 24% (95% CI: 12-40%, I²=76%) and revision rate was 30% (95% CI: 19-45%, I²=64%), rising to 35% when elective exchanges for device outgrowth were included, with mechanical failures predominating. Primary surgical site infection occurred in 6% (95% CI: 3-12%, I²=0%). Risk of bias was moderate to serious across all studies. CONCLUSION: PDDD provides moderate short-term curve correction, but approximately one in four patients experiences a complication and nearly one in three requires reoperation at short-term follow-up. Reported perioperative advantages derive from only two to three uncontrolled cohorts. PDDD does not yet match PSF for reliability or percentage correction, nor VBT for reoperation rates. Pending larger comparative studies with long-term follow-up, PDDD should be considered investigational and patients counselled accordingly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Role of Caudal Screw Fixation in Outcomes of Posterior Dynamic Distracting Device for Adolescent Idiopathic Scoliosis.Journal of pediatric orthopedics · 2026
- Variability in Posterior Vault Distraction Osteogenesis Protocols and Outcome Reporting: A Systematic Review and Meta-Analysis of Distraction Protocols.The Cleft palate-craniofacial journal : official publication of the American Cleft Palate-Craniofacial Association · 2026
- A Narrative Review of Implant Density and Surgical Outcomes in Adolescent Idiopathic Scoliosis.Cureus · 2026
- Implant Characteristics in Posterior Pedicle-Screw Fusion for Adolescent Idiopathic Scoliosis: Biomechanical Principles and Clinical OutcomesBioengineering · 2026
- Vertebral body tethering: a state-of-the-art review.Spine deformity · 2026
- Spinopelvic Parameters, Degree of Correction, and Proximal Junctional Complications After Adult Spinal Deformity Surgery: A Systematic Review and Meta-analysis.Neurospine · 2026