Identifying the presence of disc herniations in lumbar spine MRI using Gemini 3.1 Pro.
Luis Rodriguez, Trisha Naidu, Nitin Chetla, Adarsh Mallepally, Rahul Kumar, Sam Duggan, Andrew Bouras, Kyle Sporn,
Johns Hopkins University School of Medicine, Baltimore, USA. · Virginia Polytechnic Institute and State University, Blacksburg, USA. tnaidu@vt.edu.
Key points
From the paper's conclusion- Gemini 3.1 Pro showed only modest, input-dependent accuracy for lumbar disc herniation detection and a pronounced tendency to over-call pathology, most markedly when a T2 sequence was provided. Specificity fell well below the ≈ 80% typically required of clinical triage tools, so the model is not currently suitable as a triage or screening aid. We present this as an exploratory, proof-of-concept evaluation; it characterizes the failure modes of an off-the-shelf generalist model on a specialized radiological task and motivates future work on volumetric/multi-slice input, task-specific fine-tuning, and decision calibration.
Abstract
PURPOSE: Lumbar disc herniation is associated with substantial morbidity, including low back pain, radicular leg pain (sciatica), sensory disturbance, and motor deficit. Magnetic resonance imaging (MRI) is central to confirming the diagnosis in symptomatic patients and to planning surgical or interventional management. Recent advances in artificial intelligence (AI) raise the possibility of automating aspects of image interpretation to improve consistency and reduce radiologist workload. This study evaluates a general-purpose large multimodal model, Gemini 3.1 Pro, for identifying disc herniations on sagittal lumbar spine MRI in a zero-shot setting. METHODS: We hypothesized that, without task-specific training, the model would show high sensitivity but limited specificity, and that paired T1- and T2-weighted input (T1 + T2) would outperform T1 alone. Using SPIDER, a public multi-center dataset of sagittal T1- and T2-weighted lumbar MRI from patients with low back pain with expert level-by-level labels, we evaluated a single paired cohort of 119 cases under two input conditions on the same cases: T1-only and T1 + T2. The mid-sagittal slice was extracted from each series and a standardized prompt forced a binary classification (herniation present vs. absent). Performance was summarized as sensitivity, specificity, accuracy, precision, and F1 with 95% confidence intervals (CIs); the paired difference in overall accuracy was tested with the exact McNemar test. A supplementary evaluation was then performed using 3-slice image stacks, testing the model's ability to process 3-D images. RESULTS: In the paired cohort (31 herniation-positive, 88 negative; prevalence 26%), T1-only input yielded sensitivity 0.58 (95% CI 0.41-0.74), specificity 0.74 (0.64-0.82), accuracy 0.70 (0.61-0.77), precision 0.44, and F1 0.50. Paired T1 + T2 input yielded sensitivity 0.77 (0.60-0.89), specificity 0.51 (0.41-0.61), accuracy 0.58 (0.49-0.67), precision 0.36, and F1 0.49. Contrary to our hypothesis, adding the T2 sequence reduced specificity and overall accuracy: T1-only was significantly more accurate than T1 + T2 in the paired comparison (exact McNemar p = 0.044), driven by a near-doubling of false positives (43 vs. 23). The false-positive burden was substantial, equivalent to 48.9 unnecessary reviews per 100 negative scans with T1 + T2. CONCLUSION: Gemini 3.1 Pro showed only modest, input-dependent accuracy for lumbar disc herniation detection and a pronounced tendency to over-call pathology, most markedly when a T2 sequence was provided. Specificity fell well below the ≈ 80% typically required of clinical triage tools, so the model is not currently suitable as a triage or screening aid. We present this as an exploratory, proof-of-concept evaluation; it characterizes the failure modes of an off-the-shelf generalist model on a specialized radiological task and motivates future work on volumetric/multi-slice input, task-specific fine-tuning, and decision calibration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The application of deep neural networks to the detection of lumbar hernias: results from the approaches based on convolutional networks and transformers.Frontiers in radiology · 2026
- Evaluating Multimodal Vision Frontier Models for Grading Neuroforaminal Stenosis on Lumbar Spine MRIs.Global spine journal · 2026
- From Pixels to Precision: Generative Artificial Intelligence as a Paradigm Shift in Spine Imaging—Technical Foundations, Clinical Applications, and the Path to Safe Clinical DeploymentNeurospine · 2026
- An accessible efficient intervertebral disc vision-language model training strategy with LLM-based retrieval method for spine MRI report generation.European journal of radiology · 2026
- Can artificial intelligence reliably support MRI-based grading of lumbar paraspinal muscle fat infiltration? A multispecialty comparison.BMC musculoskeletal disorders · 2026
- Comparison of responses from google and large language models to the top frequently asked questions on lumbar spinal stenosis: an evaluation of accuracy and completeness.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026