Intraoperative bedside lung-ultrasound use to optimize positive end-expiratory pressure for elective robotic-assisted radical prostatectomy or cystectomy: a randomized clinical trial.
Nazmy Edward Seif, Ashgan Raouf Ali, Heba Ismail Ahmed, Mustafa Emam Mohamed
Department of Anesthesia, Surgical Intensive Care, and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt. · Department of Anesthesia, Surgical Intensive Care, and Pain Management, Faculty of Medicine, Cairo University, Cairo, Egypt. mustafaemam931@gmail.com.
Key points
From the paper's conclusion- Intraoperative LUS-guided individualized PEEP optimization significantly reduced the incidence of postoperative atelectasis and improved dynamic lung compliance without compromising hemodynamic stability in patients undergoing RARPC. Lung ultrasound offers a practical, effective, and non-invasive bedside tool for optimizing ventilation in high-risk surgical settings.
Abstract
PURPOSE: This study evaluated efficacy and safety of intraoperative individualized stepwise positive end-expiratory pressure (PEEP) titration guided by lung ultrasound (LUS) in reducing pulmonary atelectasis and complications in patients undergoing robotic-assisted radical prostatectomy or cystectomy (RARPC). METHODS: This randomized trial included 88 patients undergoing elective RARPC. Patients were assigned to either standard ventilation (PEEP 4 cmH₂O; group C) or LUS-guided stepwise PEEP titration up to 12 cmH₂O (group R). Patients, outcome assessors, and the data analyst were blinded. The primary outcome was analyzed using a linear mixed-effects model, estimating the between-group difference in LUS score at 2 h after surgery. RESULTS: Group R showed significantly lower total LUS scores at 2 h after surgery (adjusted difference: -1.68, 95%CI: -2.89 to -0.47; p = 0.007) compared to group C. Likewise, significantly lower LUS scores were observed in Group R from the end of surgery onward. PEEP titration progressively reduced post-pneumoperitoneum atelectasis rates from 50% to 9.1%, at a highest PEEP level of 12 cmH₂O. Dynamic lung compliance in group R was significantly greater at Top compared with the control group (58.93 ± 3.48 vs. 49.91 ± 5.74 mL/cmH₂O; p < 0.001). Heart rate, mean arterial pressure, oxygen saturation, and end-tidal CO₂ were comparable at all time points. Both groups were comparable for intraoperative hypotension and bradycardia. CONCLUSION: Intraoperative LUS-guided individualized PEEP optimization significantly reduced the incidence of postoperative atelectasis and improved dynamic lung compliance without compromising hemodynamic stability in patients undergoing RARPC. Lung ultrasound offers a practical, effective, and non-invasive bedside tool for optimizing ventilation in high-risk surgical settings. TRIAL REGISTRATION AND PROTOCOL: This study was registered in ClinicalTrials.gov in March 2024 (ID: NCT06307704). The trial protocol is available through the ClinicalTrials.gov registry at https://clinicaltrials.gov/study/NCT06307704 .
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ventilation distribution assessed by electrical impedance tomography during robot-assisted laparoscopic prostatectomy: A randomized controlled trial.Medicine · 2026
- Individualized Positive End-Expiratory Pressure and Postoperative Pulmonary Outcomes in Laparoscopic and Robotic Abdominal-Pelvic Surgery: A Systematic Review and Meta-Analysis.Cureus · 2026
- Effect of Ultrasound-Guided versus Conventional Lung Recruitment on End-of-Surgery Atelectasis in Adults Aged 45-74 Years Undergoing Prone-Position Spinal Surgery: A Randomized Controlled Trial.Therapeutics and clinical risk management · 2026
- Effects of pneumoperitoneum pressure on perioperative atelectasis assessed using lung ultrasonography in patients undergoing robotic-assisted laparoscopic gynaecological surgery: A prospective, randomised controlled trial.Anaesthesia, critical care & pain medicine · 2026
- Intraoperative Driving Pressure–Guided High PEEP vs Standard Low PEEP for Postoperative Pulmonary ComplicationsJAMA · 2025
- Effect of electrical impedance tomography-guided positive end-expiratory pressure optimisation on postoperative pulmonary complications in laparoscopic colorectal surgery: a randomised controlled trial.British journal of anaesthesia · 2026