Neural Computing and Applications

MSRANetV2: An explainable deep learning architecture for multi-class classification of colorectal histopathological images

Ovi Sarkar, Md Shafiuzzaman, Md. Faysal Ahamed, Golam Mahmud, Muhammad E. H. Chowdhury

Computational

Key points

From the paper's conclusion
  • We evaluated our model on a five-fold stratified cross-validation strategy on two publicly available datasets: CRC-VAL-HE−7 K and NCT-CRC-HE−100 K.

Abstract

Colorectal cancer (CRC) is a leading worldwide cause of cancer-related mortality, and the role of prompt precise detection is of paramount interest in improving patient outcomes. Conventional diagnostic methods such as colonoscopy and histological examination routinely exhibit subjectivity, are extremely time-consuming. Through the development of digital pathology, deep learning algorithms have become a powerful approach in enhancing diagnostic precision and efficiency. In our work, we proposed an architecture named MSRANetV2, specially optimized for the classification of colorectal tissue images. The model employs a ResNet50V2 backbone, extended with residual attention mechanisms and squeeze-and-excitation blocks, to extract deep semantic and fine-grained spatial features. In comparison with existing architectures, MSRANetV2 presents a multi-scale residual attention fusion strategy with squeeze-and-excitation blocks to dynamically recalibrate channel-wise features and emphasize informative spatial regions, aiming to enhance representational richness and class separability. These improvements address common limitations in baseline networks, such as vanishing gradient issues and weak localization within complex histological textures. We evaluated our model on a five-fold stratified cross-validation strategy on two publicly available datasets: CRC-VAL-HE−7 K and NCT-CRC-HE−100 K. The proposed model achieved remarkable average precision, recall, F1-score, AUC, and test accuracy of 0.9884 ± 0.0151, 0.9900 ± 0.0151, 0.9900 ± 0.0145, 0.9999 ± 0.0001, and 0.9905 ± 0.0025, respectively, on the 7 K dataset. Similarly, on the 100 K dataset, it reached 0.9904 ± 0.0091, 0.9900 ± 0.0071, 0.9900 ± 0.0071, 0.9996 ± 0.0002, and 0.9902 ± 0.0006. Additionally, Grad-CAM visualizations were incorporated to enhance model interpretability by localizing tissue areas that are medically relevant.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers