Increased interpretability of simultaneous peak water flow estimation using monotonic neural networks
Sheena Fernandez, Lynne Jack, Sarat Dass
Key points
From the paper's conclusion- The findings suggest that designing for the 98th-percentile SPWF level provides adequate capacity to satisfy the peak water demand of the multi-residential case-study buildings.
Abstract
Simultaneous peak water flow (SPWF) is calculated during building design and construction to inform the design flow, which dictates the sizing of the water supply system. SPWF represents the maximum instantaneous water flow rate and has been evaluated at the 99th percentile since the first development of estimation models in 1940. This percentile represents the satisfactory performance at which water is delivered to the building occupants - in this case, 99% of the time the water is supplied with sufficient volume and pressure, while adhering to health and safety regulations, despite any number of simultaneous uses. However, this value has not been justified nor re-evaluated and was taken as the standard value in succeeding model developments. To address this gap, this study examines different percentile levels of satisfactory performance in building water supply to evaluate the current 99th percentile and assess the most efficient level for the given case study buildings. A monotonic neural network was employed in a water fixture use probability optimization framework to model the SPWF at different quantiles. Incorporating monotonicity into the network enhances the model’s interpretability and the robustness of the results, enabling flexible evaluation across different levels. It was shown that the peak water demand of the multi-residential case study buildings can be met at a 98th percentile SPWF. The findings suggest that designing for the 98th-percentile SPWF level provides adequate capacity to satisfy the peak water demand of the multi-residential case-study buildings. Choosing the 98th percentile resulted in a reduction of up to 17.36 L/s, which is around 87.26% reduction compared to design flows from building codes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Resolution Water Consumption Profiles in University Dormitories: Implications for Sustainable Water Supply System Design and OperationSustainability · 2026
- Low-Resolution Monthly Billing Data for Residential Water Demand Management: A Profile-Based Approach to Apartment-Level Characterization and ForecastingEnvironmental Challenges · 2026
- Physics-constrained interpretable baseline modelling of wastewater lift-pump energy efficiency and its engineering validation.Journal of environmental management · 2026
- A Proposed Methodological Framework for Data-Driven Deep Learning Surrogate Modelling of Non-Revenue Water Prediction and Operational Control in Small-Sized Municipal Water Distribution SystemsAlgorithms · 2026
- Low-Level Wind Speed Analysis Methods: A Comprehensive Review and Periodic Table Classification Framework with Reproducible BenchmarksWind · 2026
- Probabilistic electrical power demand forecasting with uncertainty quantificationarXiv · 2026