Limitations of employing a unified physiological equivalent temperature scale for assessing thermal comfort in Taiwan's Cwa urban climate.
Kang-Ting Tsai, Ning-Shiang Chen, Jia-Yu Jhang
Program of Landscape and Recreation, National Chung Hsing University, 145 Xingda Rd, Taichung, 402, Taiwan. · Program in Industrial and Smart Technology, National Chung Hsing University, No. 15, Guangming Rd, Nantou City, Nantou County, 540, Taiwan. ningshiangchen@gmail.com.
Key points
From the paper's conclusion- The results indicate that a neutral temperature for these sites is 23.3 °C mPET and that a 90% acceptable thermal comfort range is between 21.4 and 25.8 °C mPET.
Abstract
Taiwan's national reference for outdoor thermal comfort assessment originates from a single non-urban site in a Cfa zone, whereas the country's most heat-vulnerable metropolitan areas lie in the Cwa zone. Conventional thermal comfort evaluations rely on single standardized scales, which may not fully reflect variation across different climates and outdoor contexts. This study employed the modified physiologically equivalent temperature (mPET) thermal index as a thermal comfort indicator and established a regionally adaptive and mPET-based thermal perception scale suitable for Taiwan's Cwa climate. Field studies were conducted in two representative Cwa sites-Zhongxing New Village and the Central Taiwan Science Park-and encompassed seven outdoor spaces with distinct spatial functions and microclimatic characteristics. Microclimatic measurements, questionnaire surveys, and user count observations were considered to examine the relationships among thermal conditions, thermal sensation, thermal comfort, and spatial behavior. The results indicate that a neutral temperature for these sites is 23.3 °C mPET and that a 90% acceptable thermal comfort range is between 21.4 and 25.8 °C mPET. Behavioral thermal adaptation, including shade-seeking and time-shifting behaviors, was also observed in this study. In addition, contextual comparison with PET thresholds reported for other climate zones indicated the regional specificity of the neutral temperatures and physiologically equivalent temperature classifications derived for Taiwan's Cwa climate, suggesting that a single physiologically equivalent temperature scale may be insufficient for nationwide evaluations. The study findings highlight a need for climate-sensitive and behaviorally informed thermal comfort assessments. The results offer initial empirical support to aid with climate adaptation strategies and outdoor space planning in humid subtropical urban environments, with further validation across additional Cwa sites warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive thermal comfort in urban parks across temperate and subtropical climatesBuilding and Environment · 2026
- Seasonal outdoor thermal comfort and neutral PET thresholds in a severe cold Dwa climate city of Shenyang ChinaScientific Reports · 2026
- Outdoor Thermal Perception Characteristics and Influencing Factors Among Older Adults in Typical Old Residential Communities: A Case Study of Wuhan, ChinaLand · 2026
- Thermal Comfort Evaluation for the Rural Elderly Based on the Spatiotemporal Differentiation of Daily Activities During Summer in Xi’an, ChinaBuildings · 2026
- Human-Centred Evaluation of Outdoor Thermal Comfort in a Northern Residential Historic District: A Case Study of Dongsandao Alley, Taiyuan, ChinaSustainability · 2026
- Designing for mild winters: evidence-based thermal comfort benchmarks from urban parks in a sub-tropical cityInternational Journal of Biometeorology · 2026