Clinical outcomes and mortality predictors of peritoneal dialysis in critically ill neonates.
İhsan Yıldırım, Fatih İşleyen, Halil Aslan, Mehmet Kılıç, Aslı Okbay Güneş, Gonca Gerçel
Neonatal Intensive Care Unit, Şanlıurfa Training and Research Hospital, Şanlıurfa, Turkey. · Department of Pediatrics, Division of Neonatology, University of Health Sciences, Sancaktepe Şehit Prof. Dr. İlhan Varank Training and Research Hospital, İstanbul, Turkey. asliokbay@gmail.com.
Key points
From the paper's conclusion- Mortality remains high among neonates requiring PD. Hydrops fetalis, metabolic disorders, fluid overload, and perinatal asphyxia were independently associated with death. Early recognition of these high-risk features may improve risk stratification and clinical management.
Abstract
BACKGROUND: Peritoneal dialysis (PD) is a commonly used kidney replacement therapy for neonatal acute kidney injury (AKI), yet data on outcomes and mortality predictors remain limited. This study evaluated the clinical outcomes, complications, and mortality predictors of PD in neonates with AKI. METHODS: This retrospective cohort study included neonates who underwent PD in a tertiary neonatal intensive care unit between 2018 and 2023. Clinical characteristics, PD indications, complications, and outcomes were analysed. Survival was assessed using Kaplan-Meier analysis, and independent mortality predictors were identified using multivariable Cox regression. RESULTS: Eighty-one neonates underwent PD. Fifty-eight percent were preterm, with a median gestational age of 36 weeks and a mean birth weight of 2449.8 ± 1000.4 g. The most common indications for PD were azotemia (71.6%) and oligoanuria (48.1%). Median PD duration was 6 days, and overall mortality was 74.1%. Median survival time after catheter insertion was 8 days. Dialysate leakage was the most frequent complication (14.7%). Independent predictors of mortality were hydrops fetalis (HR 15.26, p < 0.001), inborn metabolic disorders (HR 6.82, p < 0.001), fluid overload (HR 4.43, p = 0.039), and perinatal asphyxia (HR 2.73, p = 0.024). PD was associated with significant improvements in acid-base and electrolyte parameters. CONCLUSIONS: Mortality remains high among neonates requiring PD. Hydrops fetalis, metabolic disorders, fluid overload, and perinatal asphyxia were independently associated with death. Early recognition of these high-risk features may improve risk stratification and clinical management.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predictors of mortality and technique failure in incident peritoneal dialysis patients: a competing-risks analysisBMC Nephrology · 2026
- Dialysis modality and mortality of the Contemporary Infant and Neonatal Dialysis (COINED) Cohort: a Pediatric Nephrology Research Consortium (PNRC) studyPediatric Nephrology · 2026
- Real-world modality selection and outcomes in neonatal kidney replacement therapy: a single-center cohort study.European journal of pediatrics · 2026
- Clinical Determinants and Mortality Predictors of Acute Kidney Injury in Neonates: A Five-Year Retrospective Cohort Study.Sisli Etfal Hastanesi tip bulteni · 2026
- Early Peritonitis Within the First Six Months and One-Year Mortality in Elderly Peritoneal Dialysis Patients: A Multicentre Retrospective Study.Medicina (Kaunas, Lithuania) · 2026
- Peritoneal dialysis in the treatment of neonatal acute kidney injuryPediatric Nephrology · 2026