Surgical endoscopy

AI-assisted visualization of surgical anatomy influences dissection line selection during total mesorectal excision.

Tetsuro Maruyama, Kazuya Kinoshita, Atsushi Hirata, Yuko Ikeda, Koichiro Okada, Toru Tochigi, Gaku Ohira, Michihiro Maruyama

Department of Frontier Surgery, Graduate School of Medicine, Chiba University, 1-8-1, Inohana, Chuo-Ku, Chiba, 260-8670, Japan. t.maruyama@chiba-u.jp. · Department of Frontier Surgery, Graduate School of Medicine, Chiba University, 1-8-1, Inohana, Chuo-Ku, Chiba, 260-8670, Japan.

Observational

Key points

From the paper's conclusion
  • EUREKA-assisted visualization of Nerve-like Structures, alone or combined with loose Connective Tissue, was associated with closer agreement with the expert-defined reference line during TME. Confidence was higher under all AI-assisted conditions, but higher confidence with Connective Tissue was not accompanied by closer agreement with the reference line, indicating a potential mismatch between confidence and measured performance. Because conditions were presented in a fixed order, learning and recall effects may have influenced these findings.

Abstract

BACKGROUND: Artificial intelligence (AI)-assisted visualization may support recognition of surgical anatomy, but its influence on dissection line selection remains unclear. We evaluated whether EUREKA-assisted visualization of loose connective tissue and nerve-like structures affects agreement with an expert-defined reference line and surgeons' confidence during total mesorectal excision (TME). METHODS: This single-center simulation study included six TME scenes with potential ambiguity in dissection line selection and 20 surgeons. Each scene was presented in a fixed order under four conditions: Original, Connective Tissue, Nerve-like Structures, and Combined Overlay. Participants selected the next intended dissection line and rated confidence on a 0-4 scale. Agreement with the reference line was assessed using the Dissection Line Accuracy Score (DLAS; 0-4) and Dissection Line Deviation Area (DLDA). DLAS and confidence were analyzed using ordinal logistic mixed-effects models, and DLDA was analyzed separately by scene using linear mixed-effects models. RESULTS: A total of 480 evaluations were analyzed. Compared with Original, the odds of a higher DLAS were greater with Nerve-like Structures (odds ratio [OR], 4.05; 95% confidence interval [CI] 2.08-7.88) and Combined Overlay (OR, 8.54; 95% CI 4.01-18.21), but not with Connective Tissue (OR, 1.47; 95% CI 0.81-2.66). Confidence was higher with Connective Tissue (OR, 4.05; 95% CI 2.35-6.95), Nerve-like Structures (OR, 10.49; 95% CI 5.87-18.78), and Combined Overlay (OR, 29.99; 95% CI 15.85-56.71); all Holm-adjusted P < 0.001. Combined Overlay was most consistently associated with reduced DLDA across the six scenes. CONCLUSIONS: EUREKA-assisted visualization of Nerve-like Structures, alone or combined with loose Connective Tissue, was associated with closer agreement with the expert-defined reference line during TME. Confidence was higher under all AI-assisted conditions, but higher confidence with Connective Tissue was not accompanied by closer agreement with the reference line, indicating a potential mismatch between confidence and measured performance. Because conditions were presented in a fixed order, learning and recall effects may have influenced these findings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers