Bowel preparation and adenoma detection in AI-assisted colonoscopy.
Giacomo Mulinacci, Roberto Frego, Marta Maino, Alessandro Ettore Redaelli, Ilaria Ripamonti, Marco Emilio Dinelli, Clara Benedetta Conti
Interventional Endoscopy Unit, Fondazione IRCCS San Gerardo dei Tintori, Via Pergolesi 3, Monza, Italy. giacomo.mulinacci@irccs-sangerardo.it. · Interventional Endoscopy Unit, Fondazione IRCCS San Gerardo dei Tintori, Via Pergolesi 3, Monza, Italy.
Key points
From the paper's conclusion- Excellent bowel preparation quality was not associated with higher ADR or APC compared with good bowel preparation in this cohort. Female sex, BMI, and timing of colonoscopy were independently associated with ADR, despite the use of computer-aided detection systems.
Abstract
BACKGROUND AND AIM: Artificial intelligence (AI)-assisted colonoscopy improves adenoma detection rate (ADR), but it is currently unknown whether it performs better with excellent vs good bowel cleansing. This study aims to evaluate the association between bowel cleansing with ADR and adenomas per colonoscopy (APC) in average-risk patients undergoing AI-assisted colonoscopy. METHODS: Prospective single-centre study. Consecutive average-risk patients undergoing AI-assisted colonoscopy were enrolled from December 2025 to March 2026. Demographic and endoscopic variables were collected. Bowel preparation quality was assessed using the Boston Bowel Preparation Scale (BBPS); adequate cleansing was defined as BBPS ≥ 6 and classified as good (6-7) or excellent (≥ 8). Univariable and multivariable regression analyses identified variables associated with ADR and APC. RESULTS: A total of 425 patients were included. The overall ADR and APC were 0.35 and 0.6, respectively. Bowel preparation quality was not associated with ADR or APC. On multivariable analysis, ADR was associated with: BMI (OR 1.05, p = 0.041), female sex (OR 0.39, p < 0.001) and afternoon examinations (OR 0.39, p = 0.013). Female sex (IRR 0.53, p < 0.001) and higher BMI (IRR 1.05, p = 0.031) were independently associated with APC. CONCLUSIONS: Excellent bowel preparation quality was not associated with higher ADR or APC compared with good bowel preparation in this cohort. Female sex, BMI, and timing of colonoscopy were independently associated with ADR, despite the use of computer-aided detection systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of an Artificial Intelligence-Based Computer Aided Detection System (CADe) on Colonoscopies Performed in Hawai'i.Hawai'i journal of health & social welfare · 2026
- Colorectal Lesion Detection According to Daily Procedure Order with and Without Artificial Intelligence: An Exploratory Secondary Analysis of a Randomized Trial.Life (Basel, Switzerland) · 2026
- Effectiveness of artificial intelligence-assisted colonoscopy for colorectal lesion detection: a systematic review and meta-analysis of randomized controlled trials.BMC medical imaging · 2026
- AI-assisted second forward-view examination of the right colon significantly improves the adenoma detection rate: a multicenter randomized controlled trial.The American journal of gastroenterology · 2026
- A prospective study evaluating an artificial intelligence-based system for withdrawal time measurementEndoscopy · 2025
- The yield of artificial intelligence (GI genius) in Lynch syndrome -A randomized tandem-colonoscopy trial.Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2026