The surgeon in the loop: automation bias and human-AI interaction in robotic surgery.

Maria Clara Morais, Aditya Amit Godbole, Emaad Iqbal, Jeffrey Nussbaum, Harsh Prasanna Khare, Mattia Ballo, Filippo Filicori

Intraoperative Performance Analytics Laboratory, Department of Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA. drmariamorais@gmail.com. · Intraoperative Performance Analytics Laboratory, Department of Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA.

Key points

From the paper's conclusion
  • Surgeons accepted approximately 3 of every 5 incorrect AI recommendations. As intraoperative AI systems approach deployment, surgeon oversight cannot be assumed to neutralize algorithmic error; it must be empirically measured, deliberately designed for, and prospectively validated.

Abstract

INTRODUCTION: Artificial intelligence systems for intraoperative surgical guidance are approaching clinical deployment, yet no study has quantified automation bias (defined as the tendency to over-rely on automated recommendations) in the context of surgical decision-making. As these systems enter operative workflows, the surgeon's ability to recognize and override incorrect AI guidance becomes a critical safety requirement. AIM: To measure the extent to which surgeons modify incision plans after exposure to AI-labeled visual guidance and to determine the rate at which incorrect AI suggestions are accepted. METHODS: A two-phase controlled experiment was conducted among 19 surgeons (10 residents, 2 fellows, 7 attendings). Participants drew incision lines on 20 static frames from robotic cholecystectomy videos, first without guidance (Phase 01) and then with a mock AI overlay (Phase 02). Overlays were either correct (derived from expert consensus) or deliberately incorrect (shifted toward unsafe anatomy) at an approximately 70:30 ratio. No actual AI model was used. The primary outcome was mean perpendicular distance (MPD) between Phase 01 and Phase 02 lines. Secondary outcomes included AI-corridor adherence, over-reliance and under-reliance rates, behavioral accuracy, and confidence shift. RESULTS: Across 231 paired observations, MPD did not differ significantly between correct (75.5 pixels; SD, 33.4) and incorrect (71.1 pixels; SD, 31.7) overlay conditions (P = .35). Directional analysis revealed that surgeons accepted incorrect AI suggestions in 60.6% of incorrect-overlay frames (43/71), with a specificity for rejecting incorrect guidance of only 39.4% (28/71). Correct suggestions were accepted 76.9% of the time (123/160). Overall behavioral accuracy was 65.4%. Self-reported confidence increased significantly after AI exposure (Δ = + 0.65; P < .001). CONCLUSION: Surgeons accepted approximately 3 of every 5 incorrect AI recommendations. As intraoperative AI systems approach deployment, surgeon oversight cannot be assumed to neutralize algorithmic error; it must be empirically measured, deliberately designed for, and prospectively validated.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers