Key points
From the paper's conclusion- This first United States experience demonstrates that robotic inguinal hernia repair using Dexter is feasible and safe in the outpatient setting, with favorable outcomes, efficient operative times, and a rapid learning curve among experienced surgeons.
Abstract
BACKGROUND: Robotic-assisted inguinal hernia repair continues to evolve with the introduction of novel surgical platforms designed to improve costs, workflow integration, and ergonomics. The Dexter Surgical System has recently entered clinical practice; however, its use for inguinal hernia repair in the USA has not been reported. This study evaluated feasibility, safety, and early operative outcomes in a United States cohort. METHODS: A retrospective review was conducted of consecutive patients undergoing robotic inguinal hernia repair with Dexter at a single academic center between November 2024 and November 2025. Primary outcomes included intraoperative complications, device-related adverse events, and conversion to open or laparoscopic surgery. Secondary outcomes included operative time, console time, docking time, length of stay, and 30-day outcomes. Learning curve analysis was performed using cumulative sum methodology, along with a comparison of the primary surgeon's first five versus final five cases. RESULTS: Twenty-six patients underwent robotic inguinal hernia repair performed by two fellowship-trained minimally invasive surgeons with extensive prior robotics experience. All procedures were completed without conversion, complications, or device-related events, and all patients were discharged the same day. Mean operative time was 63.1 ± 18.5 min, with mean console time of 38.5 ± 15.7 min and docking time of 6.1 ± 2.2 min. One patient (3.8%) developed postoperative pneumonia requiring admission and intravenous antibiotics; no other 30-day complications, readmissions, or reoperations occurred. CUSUM analysis identified an inflection point at case six, after which operative times trended below the mean. Mean operative time decreased from 66.8 ± 11.1 min in the first five cases to 54.0 ± 13.3 min in the final five. CONCLUSION: This first United States experience demonstrates that robotic inguinal hernia repair using Dexter is feasible and safe in the outpatient setting, with favorable outcomes, efficient operative times, and a rapid learning curve among experienced surgeons.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early implementation of the Medtronic Hugo™ RAS system for hernia repair: a prospective evaluation of the transition phase for robotics-naïve surgeons.Surgical endoscopy · 2026
- Robotic versus laparoscopic minimally invasive inguinal hernia repair: randomized clinical trial (the ROGER trial)British journal of surgery · 2025
- Comparative outcomes of robotic versus laparoscopic inguinal hernia repair: a systematic review and meta-analysisJournal of Robotic Surgery · 2026
- Single-port robotic totally extraperitoneal inguinal hernia repair using a floating docking technique with the da Vinci SP system: feasibility across a spectrum of hernia complexity.Journal of abdominal wall surgery : JAWS · 2026
- Short-term outcomes of robotic-assisted versus laparoscopic inguinal hernia repair: a single-center retrospective study in Taiwan.Frontiers in surgery · 2026
- A comparative analysis of short-term outcomes between robotic, laparoscopic, and open inguinal hernia surgery in the emergency general surgery population.Surgery · 2026