Surgical endoscopy

Transverse versus longitudinal mucosotomy during peroral endoscopic myotomy: results of a multicenter randomized controlled trial.

Jesús Antonio Rodríguez-Fajardo, Juan Sebastián Frías-Ordoñez, Hernando Marulanda-Fernandez, William Otero-Regino, Gilberto Jaramillo-Trujillo

Department of Gastrointestinal Surgery and Digestive Endoscopy, Clínica Shaio, Bogotá, Colombia. · Department of Gastroenterology, Universidad Nacional de Colombia, Bogotá, Colombia. jsfriaso@unal.edu.co.

Randomised · n=140

Key points

From the paper's conclusion
  • In a multicenter randomized trial, transverse mucosotomy during POEM improved intraoperative efficiency and reduced gas-related events without compromising short-term safety. These findings support mucosal entry orientation as a modifiable technical factor that may optimize procedural workflow and resource utilization in submucosal endoscopic surgery.

Abstract

BACKGROUND AND AIMS: Peroral endoscopic myotomy (POEM) is an established first-line therapy for achalasia; however, technical variability persists in key procedural steps. The optimal orientation of mucosal entry remains uncertain. We evaluated whether transverse mucosotomy improves procedural efficiency and reduces gas-related events compared with the conventional longitudinal approach. METHODS: In this multicenter, parallel-group randomized clinical trial conducted at three tertiary centers, 140 adults undergoing POEM were assigned (1:1) to a standardized 15-mm transverse or longitudinal mucosotomy. The primary outcome was time from initial mucosal incision to effective entry into the submucosal tunnel, assessed by independent anonymized video review using predefined objective timestamp criteria. Secondary outcomes included need for hemostasis, mucosotomy closure time, number of clips used, gas-related events, and 30-day complications. Analyses followed the intention-to-treat principle. RESULTS: All randomized patients were included in the primary analysis. Transverse mucosotomy significantly reduced time to submucosal entry (median 228 vs. 269 s; adjusted mean difference - 44 s; 95% CI - 78 to - 10), need for hemostasis (38.6% vs. 57.1%; relative risk 0.68; 95% CI 0.49-0.95), closure time (662 vs. 1020 s; p < 0.001), and number of clips used (median 3 vs. 7; rate ratio 0.44; 95% CI 0.36-0.54). Pneumoperitoneum occurred less frequently with the transverse approach (34.3% vs. 51.4%; relative risk 0.67; 95% CI 0.46-0.97). Rates of serious adverse events and 30-day readmission were low and comparable between groups. CONCLUSIONS: In a multicenter randomized trial, transverse mucosotomy during POEM improved intraoperative efficiency and reduced gas-related events without compromising short-term safety. These findings support mucosal entry orientation as a modifiable technical factor that may optimize procedural workflow and resource utilization in submucosal endoscopic surgery. CLINICAL TRIALS REGISTRY: NCT07425977.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers