Traction method with pulley maneuver in minimally invasive hepatobiliary pancreatic surgery: how I do it differently?
Daegwang Yoo
Division of Hepatobiliary and Pancreatic Surgery, Department of Surgery, Seoul Soonchunhyang University Hospital, Soonchunhyang University College of Medicine, 59, Daesagwan-Ro, Yongsan-Gu, Seoul, 04401, South Korea. yoodaegwang@naver.com.
Key points
From the paper's conclusion- The "Pulley maneuver" using the Stratafix symmetric barbed suture represents a valuable technical variation in minimally invasive hepatobiliary and pancreatic surgery. Its versatility, ease of application, and superior tissue-holding capabilities make it an essential tool for optimizing the surgical field, ultimately enhancing patient safety and surgical outcomes.
Abstract
BACKGROUND: Achieving optimal traction and exposure in minimally invasive hepatobiliary and pancreatic surgery remains a significant challenge, often necessitating additional ports or assistants. This article describes novel traction techniques utilizing the Stratafix® symmetric barbed suture, repurposed from its original wound closure design, to enhance surgical efficiency and control. METHODS: We detail the "Pulley maneuver," a versatile approach for various hepatobiliary and pancreatic procedures. Key modifications include a "Sling pulley maneuver with Endo-loop" for pancreatic elevation during distal pancreatectomy, a "traction of vascular structure with vessel loop" for precise hilar lymph node dissection, and a "traction of gallbladder" technique to provide an additional "hand" in robotic single-site cholecystectomy. The Stratafix suture's unique symmetrical anchors offer superior tissue-holding strength, allowing for dynamic, multi-directional tension adjustments without knot tying. RESULTS: This repurposing offers a simple, effective, and reproducible solution to exposure challenges. It enhances surgical ergonomics through stable, hands-free retraction, improves visualization of critical structures, and potentially reduces the need for additional trocars or assistants. The ability to create adjustable traction points with minimal equipment is a significant advantage in complex cases. CONCLUSION: The "Pulley maneuver" using the Stratafix symmetric barbed suture represents a valuable technical variation in minimally invasive hepatobiliary and pancreatic surgery. Its versatility, ease of application, and superior tissue-holding capabilities make it an essential tool for optimizing the surgical field, ultimately enhancing patient safety and surgical outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bimanual technique for biportal endoscopic spine surgery: technical pearls to enhance surgical performance.Neurosurgical focus · 2026
- Elastic Intracorporeal Retraction in Laparoscopic Bariatric Surgery: Performance, Safety, and Multi-Organ Applications.Obesity surgery · 2026
- Multi‐Loop Traction Device‐Assisted Papillary Traction During Single‐Balloon Enteroscopy‐Assisted Endoscopic Retrograde Cholangiopancreatography After Roux‐en‐Y Gastrectomy: A Four‐Case SeriesDEN Open · 2026
- Balloon-assisted ERCP for bile duct stones in surgically altered anatomy: current techniques, devices, and evolving strategiesTherapeutic Advances in Gastroenterology · 2025
- A Two-Handed Technique in Biportal Endoscopic Spine Surgery Using an Endoscopic Self-Retractor for Resection of Ossification of Ligamentum Flavum in Thoracic Spine.Clinical spine surgery · 2026
- How-I-do-it: bottom dock eTEP with bilateral TAR for incisional hernia after liver transplantation: early outcomes and feasibility.Surgical endoscopy · 2026