Quantitative analysis of da Vinci 5 force feedback technology in robotic rectal surgery: a preliminary pilot study
Yusuke Nishi, Yasumitsu Hirano, Yasuhiro Ishiyama
Saitama Medical University
Key points
From the paper's conclusion- We retrospectively analyzed 13 consecutive robotic rectal cancer resections performed by a single expert surgeon.
Abstract
BACKGROUND: The da Vinci 5 (DV5) introduces force feedback (FFb) technology to robotic surgery, aiming to enhance safety through haptic sensation. However, its quantitative impact on specific tissue manipulations in rectal cancer surgery remains unclear. This study evaluated the clinical significance of FFb by analyzing force metrics across different instrument roles. METHODS: We retrospectively analyzed 13 consecutive robotic rectal cancer resections performed by a single expert surgeon. Force data were extracted from system logs for the Cadiere Forceps (static retraction) and Fenestrated Bipolar Forceps (dynamic retraction). Comparisons were made between three settings: Off (N = 3), Low (N = 11), and Medium (N = 5). For "Low" and "Medium" settings, cases overlapped as settings were adjusted intraoperatively. Cumulative force usage time was calculated for each setting. Statistical significance was assessed using the Kruskal-Wallis test. RESULTS: A total of 91,000 + seconds for Cadiere and 68,000 + seconds for Fenestrated Bipolar forceps were analyzed. For the Cadiere Forceps (static retraction), the mean force was significantly reduced as FFb sensitivity increased (Off: 3.07 N, Low: 2.58 N, Medium: 2.03 N; P = 0.039). For the Fenestrated Bipolar Forceps (dynamic retraction), while the mean force showed no significant difference, the median maximum (peak) force was significantly suppressed with higher FFb settings (Off: 36.19 N, Low: 18.82 N, Medium: 10.06 N; P = 0.033). No intraoperative complications related to tissue trauma occurred. CONCLUSIONS: FFb technology in the DV5 effectively modulates surgical force based on the functional role of the instrument. It significantly reduces sustained stress during static retraction and serves as a "safety brake" to cap peak forces during dynamic maneuvers, potentially enhancing the safety of robotic rectal surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Forceps Load During Robot-Assisted Colorectal Surgery Using the da Vinci 5: A Single-Center Analysis of Force Feedback Data.The American surgeon · 2026
- Force feedback and vocal cord dysfunction after robotic esophagectomy: a comparison of the da Vinci 5 and Xi systems.Journal of robotic surgery · 2026
- Operative efficiency and short-term outcomes of da Vinci 5 versus da Vinci Xi in robotic rectal cancer surgery: an overlap-weighted cohort study with an exploratory case insights analysis.Journal of robotic surgery · 2026
- Impact of the force feedback feature on transoral robotic surgery.Journal of robotic surgery · 2026
- Motor learning with force feedback instruments among laparoscopic surgeons and residents.Journal of robotic surgery · 2026
- Bedside Assistant Suction Response and Visual Field Recovery During Robot-Assisted Rectal Cancer Surgery: An Exploratory Propensity Score-Matched Comparison of Assistant-Access Workflows Using Hinotori and da Vinci Xi.Asian journal of endoscopic surgery · 2026