From precision to strength: computer vision for suture quality assessment—an ex vivo pilot study
Roberto Spagnulo, Francesco Marzola, Federica Corso, Giovanni Distefano, Matteo Pescio, Kengo Hayashi, Federica Barontini, Giulio Dagnino,
University of Turin · Politecnico di Torino
Key points
From the paper's conclusion- While spatial metrics correlate with mechanical resistance, they appear insufficient as standalone indicators of suture quality.
Abstract
Abstract Background Suturing is the cornerstone of surgical practice, yet its assessment continues to rely on subjective evaluation. As minimally invasive techniques become increasingly central in surgery, the demand for precision grows. In this context, the present pilot study aims to investigate whether spatial metrics of suture placement can quantitatively reflect mechanical performance and to determine how operator experience and surgical platform influence technical outcomes. Methods Fifteen participants, stratified by prior experience in minimally invasive surgery, performed standardized suturing tasks on porcine rectal specimens using three platforms: conventional laparoscopy, the daVinci Research Kit (dVRK), and the Flex robotic endoscope. Quantitative Suture Assessment was conducted by extracting spatial features (e.g., distance variability between consecutive stitches), while mechanical resistance was evaluated via intraluminal burst pressure. Statistical analyses included correlation and regression modeling to assess the relationship between spatial metrics and burst pressure, as well as comparative analyses across platforms and experience levels. Results Mean burst pressures measured 17.38 ± 6.54 mmHg for laparoscopy, 15.99 ± 7.69 mmHg for dVRK, and 13.60 ± 10.08 mmHg for Flex. Masters recorded a mean burst pressure of 17.95 ± 9.43 mmHg, while Advanced 13.89 ± 7.41 mmHg and Beginners 15.13 ± 7.64 mmHg. Laparoscopy achieved higher burst pressures than Flex, and dVRK outperformed Flex among Beginners. Laparoscopy and dVRK were faster than Flex, with Masters completing tasks more rapidly across all platforms. Spacing irregularity was negatively correlated with burst pressure (p < 0.05). However, the XGBoost model trained on all variables exhibited poor performance (R 2 = -0.42, MSE = 93.7), and high multicollinearity. Conclusions Platform-specific scores emerged with limitations. While spatial metrics correlate with mechanical resistance, they appear insufficient as standalone indicators of suture quality. Ultimately, this approach could pave the way toward intelligent, intraoperative systems capable of delivering real-time feedback, with implications for both surgical education and quality assurance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Developing and evaluating image-based metrics for open surgical suturing skill assessment.Global surgical education : journal of the Association for Surgical Education · 2026
- Objective assessment of robot-assisted suturing using a weighted performance score and a virtual simulation platform.Journal of robotic surgery · 2026
- Under the Microscope: Expert Novice Gaze Differences During Suturing ETRA019Proceedings of the ACM on Human-Computer Interaction · 2026
- Interpretable video-derived markers of surgical experience during robotic suturing: a proof-of-concept study in an ex vivo porcine model.Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy · 2026
- OSS: Open suturing skills vision-based assessment challenge 2024-2025.Medical image analysis · 2026
- A Task-Specific Performance Rating Scale for Laparoscopic Intracorporeal Suturing and Knot Tying: Development and Initial Evaluation.Journal of laparoendoscopic & advanced surgical techniques. Part A · 2026