Bioprocess and biosystems engineering

pH-associated acidification states and downstream digester stability in full-scale food waste anaerobic digestion.

Mingyue Zheng, Kaijun Wang, Yuanyuan Wu, Hainan Gan

School of Bioengineering, Beijing Polytechnic University, Beijing, 100176, China. · State Key Joint Laboratory of Environment Simulation and Pollution Control, School of Environment, Tsinghua University, Beijing, 100084, China. wkj@tsinghua.edu.cn.

Key points

From the paper's conclusion
  • This study monitored a 200 t d- 1 full-scale food waste treatment plant for 93 d to characterize pH-associated acidification states in a homogenization tank and their relationship with downstream digester performance.

Abstract

Stable full-scale anaerobic digestion of food waste can be constrained when rapid front-end acidification exceeds the conversion capacity of the downstream digester. This study monitored a 200 t d- 1 full-scale food waste treatment plant for 93 d to characterize pH-associated acidification states in a homogenization tank and their relationship with downstream digester performance. Actual hydraulic retention times were approximately 3 d in the homogenization tank and 30 d in the anaerobic digester. At homogenization-tank effluent pH 4.2-5.0, lactate, ethanol, and acetate dominated the quantified soluble fermentation products, accounting for 78%-83% of the measured metabolites. When pH increased to 5.5-6.5, the spectrum shifted reversibly toward a butyrate-enriched mixed-acid state. Across these states, the downstream digester maintained pH 7.59-7.63, a total volatile fatty acid concentration below 250 mg L- 1, apparent total volatile fatty acid removal above 99%, and average total chemical oxygen demand removal of approximately 88% at stage-average organic loading rates of 3.13-3.44 g COD L- 1 d- 1. Thermodynamic calculations under defined stage-specific boundary conditions showed larger energetic margins for lactate-to-acetate (- 63.0 to - 59.2 kJ mol- 1) and ethanol-to-acetate conversion (- 42.0 to - 37.3 kJ mol- 1), whereas propionate oxidation remained closest to the thermodynamic boundary (- 2.3 to - 0.8 kJ mol- 1). These results indicate that front-end product composition may provide useful operational information beyond acidification intensity alone and that lactate- and ethanol-rich states may reduce reliance on the thermodynamically constrained propionate-oxidation route.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers