Image quality and procedural safety in neonatal brain MRI with and without sedation.
Julia Greiser, Laurens Winkelmeier, Jochen Herrmann, Fabian Flottmann, Chinedu Ulrich Ebenebe
Division of Neonatology and Pediatric Intensive Care, Department of Pediatrics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany. j.greiser@uke.de. · Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
Key points
From the paper's conclusion- Neonatal MRI strategies involve a clinically relevant trade-off between image quality and procedural safety. Natural-sleep MRI avoids pharmacological exposure and was not associated with documented adverse events but resulted in more motion artefacts. MRI strategies should therefore be individualized according to clinical condition and required diagnostic image quality.
Abstract
UNLABELLED: Neontal brain magnetic resonance imaging (MRI) is susceptible to motion artefacts, whereas pharmacological sedation or anaesthesia may cause cardiorespiratory adverse events. We compared image quality and adverse events across three MRI strategies in newborns: natural sleep without sedation, pharmacological sedation, and imaging during mechanical ventilation. We retrospectively analysed 151 brain MRI examinations performed in a tertiary neonatal intensive care unit between August 2013 and August 2024. Examinations were classified as non-sedated using a feed-and-swaddle approach (n = 21), pharmacologically sedated without intubation (n = 67), or performed in intubated and mechanically ventilated infants (n = 63). Motion artefacts and documented adverse events were compared between groups. Motion artefacts were more frequent in non-sedated examinations than in sedated or intubated examinations (85.7% vs. 32.8% and 25.4%, respectively; p < 0.001). Moderate/severe artefacts occurred in 14.3%, 7.5%, and 0%, respectively. No adverse events were documented in the non-sedated group, compared with 8/67 (11.9%) in sedated and 7/63 (11.1%) in intubated infants; this difference was not statistically significant (p = 0.275). Within the sedated cohort, artefacts were more frequent with chloral hydrate, whereas respiratory complications occurred predominantly with propofol-based sedation. CONCLUSION: Neonatal MRI strategies involve a clinically relevant trade-off between image quality and procedural safety. Natural-sleep MRI avoids pharmacological exposure and was not associated with documented adverse events but resulted in more motion artefacts. MRI strategies should therefore be individualized according to clinical condition and required diagnostic image quality. WHAT IS KNOWN: • Motion artefacts may compromise neonatal MRI, and pharmacological sedation or anaesthesia is frequently used to improve image quality. • Feed-and-swaddle MRI can avoid drug exposure, while sedative and anaesthetic agents may cause respiratory and haemodynamic adverse events. WHAT IS NEW: • Direct comparison of three real-world neonatal MRI strategies demonstrates a trade-off between image quality and procedural safety: sedation and controlled ventilation reduced motion artefacts, whereas no adverse events were documented during natural-sleep MRI. • Exploratory analyses suggest differences between sedation regimens, with more artefacts after chloral hydrate and respiratory events occurring predominantly with propofol-based sedation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sedation/anesthesia use for inpatient pediatric brain MRIs: National trends and outcomes.Journal of hospital medicine · 2026
- Ketamine-Based Sedation Among Young Infants During MRI at Mzuzu Central Hospital: Initial Experience in a Resource-Limited Setting in Malawi.Malawi medical journal : the journal of Medical Association of Malawi · 2026
- Cerebral Hemodynamic Changes During Cardiac Surgery: A Feasibility MR Study in PigletsNMR in Biomedicine · 2026
- Data quality biases normative models derived from fetal brain MRI.Imaging neuroscience (Cambridge, Mass.) · 2026
- Clinical Evaluation of Scout Accelerated Motion Estimation and Reduction (SAMER) Motion-Corrected 2D T2-Weighted TSE 3T Brain MRI in the Neurologic Intensive Care UnitAmerican Journal of Neuroradiology · 2026