Transpulmonary pressure monitoring in neonates and infants.
Meryl Vedrenne-Cloquet, Florent Baudin, Jan Clausen, Martin C J Kneyber, Xavier Durrmeyer, Robinder G Khemani
Université Paris Cité, Inserm, UMR1141, Neurodiderot Équipequipe SleepCmd, Paris, France. meryl.vedrenne@aphp.fr. · Hospices Civils de Lyon, Hôpital Femme Mère Enfant, Service d'Urgences Et de Réanimation Pédiatriques, Bron, France.
Key points
From the paper's conclusion- PL monitoring offers a promising physiological approach to individualize respiratory support in neonates and young infants. Further studies are needed to validate minimally invasive or non-invasive surrogates of PL and to determine their clinical relevance in this population. Integration of automated occlusion maneuvers and other advanced monitoring tools into neonatal ventilators may facilitate the transition towards physiology-based, individualized respiratory and cardioprotective strategies.
Abstract
UNLABELLED: Transpulmonary pressure (PL) monitoring has been extensively studied in adult critical care, but evidence remains limited in neonates and infants despite their high vulnerability to lung and cardiac injury. This narrative review summarizes the physiological rationale, measurement techniques, and clinical evidence for PL monitoring in neonates and infants. PL is the distending pressure of the lungs. PL monitoring may help characterize lung stress and strain, assess respiratory effort, guide PEEP selection, and better understand cardiopulmonary interactions. Esophageal pressure monitoring remains the reference method for estimating PL, but its invasiveness and technical limitations restrict its use, particularly in extremely preterm neonates. Alternative approaches, including diaphragmatic electrical activity or airway occlusion maneuvers, may provide less invasive estimates, although most remain insufficiently validated in neonates. Current clinical evidence is scarce but suggests that excessive respiratory effort and elevated lung stress may occur in preterm infants, including during non-invasive respiratory support. PL monitoring may also help to optimize lung recruitment and cardiopulmonary interactions in infants with congenital heart disease or right ventricular failure. CONCLUSIONS: PL monitoring offers a promising physiological approach to individualize respiratory support in neonates and young infants. Further studies are needed to validate minimally invasive or non-invasive surrogates of PL and to determine their clinical relevance in this population. Integration of automated occlusion maneuvers and other advanced monitoring tools into neonatal ventilators may facilitate the transition towards physiology-based, individualized respiratory and cardioprotective strategies. WHAT IS KNOWN: • Neonates' physiology may increase their vulnerability to ventilator-induced injuries. • Transpulmonary pressure (PL) reflects the true lung distending pressure, but neonatal evidence remains limited and esophageal pressure monitoring is challenging. WHAT IS NEW: • Emerging alternatives (diaphragmatic electrical activity and airway occlusion maneuvers) could provide emerging approaches to estimate lung stress and respiratory effort. • PL-informed PEEP titration may help optimize lung recruitment to optimize hemodynamics in neonates with our without congenital heart disease.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Applications of lung ultrasound in preterm infants: implications for respiratory distress syndrome and bronchopulmonary dysplasia.Journal of perinatology : official journal of the California Perinatal Association · 2026
- Monitoring of regional ventilation and ventilator-induced lung injury in pediatric acute respiratory distress syndrome (MoVe lupARDS): a study protocol for a randomized controlled trial.Trials · 2026
- Neonatal Point-of-Care Lung Ultrasonography: Techniques and Normal FindingsNeoReviews · 2026
- Evolution of POCUS in the NICU: From a diagnostic tool to an extension of clinical examination.Seminars in fetal & neonatal medicine · 2026
- Effect of Nasal Continuous Positive Airway Pressure Delivered by RAM® Cannula Versus Standard Binasal Prongs on Diaphragm Electrical Activity in Very Low Birth Weight Preterm Infants: A Randomized Crossover TrialChildren · 2026
- Higher versus lower PEEP during non-invasive ventilation to stabilize preterm infants within their SpO2 target: a prospective real-life randomized cross-over trialRespiratory Research · 2026