Current quality challenges in H&E preparation: The critical foundation for increased use of digital pathology and AI emergence.
Clément Tondon, Gilles Erb, Caroline Egele, Jean-Philippe Michot, Dominique Fetique, Marie-Pierre Chenard, Jean-Pierre Bellocq
Department of Pathology, Hôpitaux Universitaires de Strasbourg, 1, Avenue Molière, Strasbourg, 67098, France. · Unaffiliated / Independent, Strasbourg, France.
Key points
From the paper's conclusion- We report that up to 25,5% of H&E slides, varying by tissue type and assessment year, exhibited technical preparation imperfection from multiple stages, including microtomic sectioning, excessive thickness, and tissue stretching.
Abstract
Hematoxylin and Eosin (H&E) glass slide preparation is fundamental to histopathology. Pathologists' expertise routinely mitigates potential issues due to quality variability into or across laboratories, ensuring diagnostic accuracy. However, as artificial intelligence (AI) induced by whole slide imaging (WSI) emerges as a future advancement in pathology, a shift toward greater technical standardisation of the preparations or adaptive algorithms deserves consideration. This study examined longitudinal data (2019-2024) from the French national external quality assessment (EQA) programme integrated with a national survey conducted in 2024. We report that up to 25,5% of H&E slides, varying by tissue type and assessment year, exhibited technical preparation imperfection from multiple stages, including microtomic sectioning, excessive thickness, and tissue stretching. Separately, 8,3% to 23,8% of slides showed suboptimal staining, characterised mainly by insufficient nucleo-cytoplasmic contrast or intensity fluctuations. Advocating sustained quality improvement to prepare for future diagnostic pathology, we emphasise that optimising pre-analytical H&E preparation quality before AI deployment is critical: robust AI performance requires consistent, high-quality inputs rather than reliance on hypothetical post-hoc algorithmic compensation. Prioritising quality at the source reduces computational burden, environmental impact, and deployment costs while enhancing ethical transparency. Our findings provide technical areas for improvement to enhance H&E testing while anticipating AI integration at scale.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Role of Whole Slide Imaging in AI-Based Digital Pathology: Current Challenges and Future Directions—An Updated Literature ReviewJournal of Molecular Pathology · 2026
- Benchmarking and Improvement of Artifact Segmentation Methods in H&E-Stained Whole Slide ImagingarXiv · 2026
- BigpictureQC: multi-stain, multi-species artifact segmentation for whole-slide quality controlBMC Medicine · 2026
- Bridging the Gap - Translating AI in Pathology into Clinical Impact.NEJM AI · 2026
- Direct Measurement and AI-based Inference Reveal Histological Section Thickness as a Variable Physical Property Accessible from Routine H&E Images.Laboratory investigation; a journal of technical methods and pathology · 2026
- OS10.4.A Technical domain shift in foundation models for histopathology: Quantification and mitigation using paired multi-institutional dataNeuro-Oncology · 2026