Langenbeck's archives of surgery

Diagnostic accuracy of surgeon-performed point-of-care ultrasonography using Tokyo guidelines criteria for acute cholecystitis: a prospective diagnostic accuracy study.

Francisco Xavier González Servín, Luis Rodrigo Barrera Guerra, Ethel Jenny García Cruz, Luis Manuel Uribe Galán, Alberto García Rodríguez, Gerardo Alvarado Romero, Edgar Balbuena Herrera

Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico. fco_x93@me.com. · Department of General Surgery, Hospital General Regional Vicente Guerrero, Instituto Mexicano del Seguro Social (IMSS), Avenida Adolfo Ruiz Cortines s/n Acapulco De Juárez, Col. Alta Progreso, Acapulco De Juárez, 39610, Guerrero, Mexico.

Guideline

Key points

From the paper's conclusion
  • Surgeon-performed point-of-care ultrasonography demonstrated excellent sensitivity and rule-out performance. When incorporated into the Tokyo diagnostic criteria, its diagnostic performance was comparable to radiology-performed ultrasonography, supporting its use as a practical diagnostic alternative in emergency surgical settings with limited access to radiology services.

Abstract

BACKGROUND: Acute calculous cholecystitis is a common surgical emergency. In health systems with delayed or limited access to radiology-performed ultrasonography, diagnostic delays may increase complications, length of stay, and resource utilization. Surgeon-performed point-of-care ultrasonography may expedite evaluation; however, its diagnostic accuracy when incorporated into structured diagnostic frameworks such as the Tokyo criteria remains uncertain. METHODS: We conducted a prospective observational diagnostic accuracy study in the emergency department of a second-level referral hospital. Adult patients with clinical suspicion of acute cholecystitis were enrolled during recruitment shifts. All participants underwent standardized clinical evaluation, surgeon-performed point-of-care ultrasonography using a handheld device, and radiology-performed ultrasonography. The reference standard was pragmatic: histopathology for operated patients and structured clinical follow-up for up to 2 months for nonoperated patients. Diagnostic performance (sensitivity, specificity, likelihood ratios, predictive values, and post-test probability) was calculated for surgeon-performed ultrasonography alone, radiology-performed ultrasonography, and the Tokyo criteria using either imaging modality. RESULTS: A total of 170 patients were included (mean age 42.8 years; 78.8% women). Surgeon-performed point-of-care ultrasonography considered positive with at least 1 sonographic finding demonstrated a sensitivity of 96.4% and specificity of 55.6%, with strong rule-out capability (negative likelihood ratio 0.06; negative post-test probability approximately 1%). Radiology-performed ultrasonography showed a sensitivity of 82.1% and specificity of 64.1%. When integrated into the Tokyo criteria, surgeon-performed ultrasonography yielded a sensitivity of 78.6% and specificity of 80.3%, comparable to Tokyo criteria using radiology-performed ultrasonography, with no statistically significant difference in paired classification. CONCLUSIONS: Surgeon-performed point-of-care ultrasonography demonstrated excellent sensitivity and rule-out performance. When incorporated into the Tokyo diagnostic criteria, its diagnostic performance was comparable to radiology-performed ultrasonography, supporting its use as a practical diagnostic alternative in emergency surgical settings with limited access to radiology services.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers