Side differences in NIRS-derived muscle oxygen saturation during treadmill running.
Lara Zwiener, Oliver Richrath, Philip Skotzke, Benjamin Volkamer-Kien, Sascha Schwindling, Tim Meyer
Institute of Sport and Preventive Medicine, Saarland University, Campus B8.2, 66123, Saarbrücken, Germany. zwienerlara@gmail.com. · Institute of Sport and Preventive Medicine, Saarland University, Campus B8.2, 66123, Saarbrücken, Germany.
Key points
From the paper's conclusion- No systematic differences between SmO2 response between the legs were found. However, wide limits of agreement suggest that individual side differences may exist. A single NIRS device may sufficiently reflect bilateral SmO2 responses at the group level, while individual side-to-side-comparisons should be interpreted with caution.
Abstract
PURPOSE: Near-infrared spectroscopy (NIRS) offers a promising non-invasive method to assess muscle oxygenation in real time. While asymmetries in muscle oxygen saturation (SmO2) between dominant and non-dominant legs have been studied in cycling, data in running are limited. Such differences may affect NIRS use in training control. This study investigated SmO2 differences between dominant and non-dominant vastus lateralis during treadmill running at three workloads using a wearable continuous-wave NIRS device. METHODS: Forty-eight participants (20 female, Age = 21.6 ± 1.5 years) performed two graded treadmill exercise tests, 14 days apart. The Moxy Monitor was placed bilaterally on the vastus lateralis to measure SmO2 and analysed across three individualized workloads (LOW, MID, HIGH). Linear mixed models were used with participant as random, and side and workload as fixed effects. To assess adipose tissue thickness (ATT) effects, a 7mm cut-off defined two subgroups (ATT<7mm, ATT>7mm). Bland-Altman plots examined mean bias and limits of agreement. RESULTS: No significant side effects were found for either group (ALL p = .759, ATT<7mm p = .713 and ATT>7mm p = .890). Bland-Altman analysis revealed a small mean bias (ALL: -0.34%, ATT<7mm: - 0.48%, ATT>7mm: -0.22%) with wide limits of agreement between the legs. CONCLUSION: No systematic differences between SmO2 response between the legs were found. However, wide limits of agreement suggest that individual side differences may exist. A single NIRS device may sufficiently reflect bilateral SmO2 responses at the group level, while individual side-to-side-comparisons should be interpreted with caution.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Visually identified breakpoints in muscle oxygen saturation are not equivalent to ventilatory thresholds in national-level triathletes.European journal of applied physiology · 2026
- Muscle Oxygenation During Exercise in Patients with Peripheral Artery Disease: A Systematic Review.Applied sciences (Basel, Switzerland) · 2026
- Sex differences and acute intermittent isometric handgrip exercise effects on microvascular reactivity in young healthy adults.Frontiers in physiology · 2026
- Near infrared spectroscopy-derived muscle oxidative capacity correlates to oxidative metabolic predictors of performance in highly trained female middle-distance runners.Physiological reports · 2026
- Evaluation of local quadriceps action response patterns during cycling using a multimodal NIRS and thermal imaging protocol: A pilot study.Acta of bioengineering and biomechanics · 2026
- Muscle oxygenation in competitive swimming: a roadmap for validating key performance indicatorsFrontiers in Sports and Active Living · 2026