Agreement between the respiratory compensation point and various critical power estimates using a step-ramp-step protocol in cyclists.
Hilkka Kontro, Martin J MacInnis
Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. hilkka.kontro@ucalgary.ca. · Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
Key points
From the paper's conclusion- In 19 cyclists, power output at respiratory compensation point (RCP) was calculated with or without correction for mean response time (MRT) and heavy-domain V̇O2 slow component, then compared against critical power (CP) estimated from laboratory-based time trials using four models.
- Power at RCP derived using a step-ramp-step protocol (RCPSRS; 246±40W) was significantly lower than uncorrected PO at RCP (303±48W) and PO at RCP estimates only correcting for MRT using the double-linear (278±47W) and moderate step (278±49W) approaches (P<0.001 for all). PO at RCPSRS was less than CP derived from the linear work-time (CPwork: 258±44 W; P=0.007) and linear power vs. 1/time models (CP1/t: 262±47 W; P<0.001) but not different from CP derived from the 2-parameter hyperbolic (CP2hyp; 256±43W; P=0.06) and 3-parameter hyperbolic (CP3hyp; 242±37W; P=0.91) models.
- Corrected RCPSRS from the single-visit SRS protocol agrees with hyperbolic-model CP values derived from multi-visit testing when estimating the maximal metabolic steady state.
Abstract
PURPOSE: Respiratory compensation point (RCP) and critical power (CP) are both used to demarcate the upper boundary of steady-state exercise; however, their agreement may vary depending on the method used to 1) translate RCP to a power output (PO) and 2) derive CP. METHODS: In 19 cyclists, PO at RCP was calculated with or without correction for mean response time (MRT)-determined by two methods-and heavy-domain V̇O2 slow component, then compared against CP estimated from laboratory-based time trials using four models. RESULTS: PO at RCP derived using a step-ramp-step (SRS) protocol (RCPSRS; 246±40W) was significantly lower than uncorrected PO at RCP (303±48W) and PO at RCP estimates only correcting for MRT using the double-linear (278±47W) and moderate step (278±49W) approaches (P<0.001 for all). PO at RCPSRS was less than CP derived from the linear work-time (CPwork: 258±44 W; P=0.007) and linear power vs. 1/time models (CP1/t: 262±47 W; P<0.001) but not different from CP derived from the 2-parameter hyperbolic (CP2hyp; 256±43W; P=0.06) and 3-parameter hyperbolic (CP3hyp; 242±37W; P=0.91) models. Limits of agreement and intraclass correlation coefficients (ICC) indicated good agreement between RCPSRS and all CP models (ICC = 0.90 to 0.93). In contrast, work capacity above CP (W') derived from CP models or the ramp test showed poor concordance with each other (ICC = 0.19 to 0.44). CONCLUSION: Corrected RCPSRS from the single-visit SRS protocol agrees with hyperbolic-model CP values derived from multi-visit testing when estimating the maximal metabolic steady state.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- In 19 cyclists, power output at respiratory compensation point (RCP) was calculated with or without correction for mean response time (MRT) and heavy-domain V̇O2 slow component, then compared against critical power (CP) estimated from laboratory-based time trials using four models.
- Power at RCP derived using a step-ramp-step protocol (RCPSRS; 246±40W) was significantly lower than uncorrected PO at RCP (303±48W) and PO at RCP estimates only correcting for MRT using the double-linear (278±47W) and moderate step (278±49W) approaches (P<0.001 for all). PO at RCPSRS was less than CP derived from the linear work-time (CPwork: 258±44 W; P=0.007) and linear power vs. 1/time models (CP1/t: 262±47 W; P<0.001) but not different from CP derived from the 2-parameter hyperbolic (CP2hyp; 256±43W; P=0.06) and 3-parameter hyperbolic (CP3hyp; 242±37W; P=0.91) models.
- Corrected RCPSRS from the single-visit SRS protocol agrees with hyperbolic-model CP values derived from multi-visit testing when estimating the maximal metabolic steady state.
Readers' thoughts
No reader thoughts yet.
Related papers
- The Respiratory Compensation Point Predicts 19.2-km Cycling Performance in Trained Male Cyclists.Journal of strength and conditioning research · 2026
- Comparison of Modelled Maximal Lactate Steady State with Critical Power in Elite Cyclists.International journal of sports medicine · 2026
- An 8-minute Self-Paced Cycling Test designed for endurance fitness monitoring: Cross-sectional validity, test-retest reliability, and practical implementation.Journal of sports sciences · 2026
- Work-to-rest ratios in repeated sprint assessments: A replication study.Sports medicine international open · 2026
- Physiological Associations, Within-Session Repeatability, and Exploratory Prediction of Peak Oxygen Uptake Using the Revised 3-Minute Seated Stepping Test in Healthy Young Japanese Adults.Journal of functional morphology and kinesiology · 2026
- Better race times without higher VO2peak: performance gains in recreational runners over 18 monthsEuropean Heart Journal · 2026