Stage-dependent differences in recalculated mean deviation between 24plus(1-2) and 24plus(1) test locations in glaucoma.
Hiroki Nomoto, Chota Matsumoto, Fumi Tanabe, Akihiko Sugino, Yukari Taguchi, Shunji Kusaka
Faculty of Medicine, Department of Ophthalmology, Kindai University, Sakai City, Osaka, Japan. nomoto@med.kindai.ac.jp. · Faculty of Medicine, Department of Ophthalmology, Kindai University, Sakai City, Osaka, Japan.
Key points
From the paper's conclusion- In this recalculation/subsampling analysis, 24plus(1)-derived MD was similar to 24plus(1-2)-derived MD in early glaucoma but diverged with advancing disease, particularly beyond approximately - 5 to - 6 dB, suggesting caution when interpreting 24plus(1)-derived MD in more advanced glaucoma.
Abstract
PURPOSE: To evaluate stage-dependent differences in mean deviation (MD) recalculated from the 24plus(1-2) and 24plus(1) test locations and to identify the MD range at which divergence between the reduced and full location sets exceeds a prespecified operational threshold in glaucoma. METHODS: This retrospective, cross-sectional study included 394 eyes from 197 patients with glaucoma including preperimetric glaucoma (PPG). The 24plus(1) MD was recalculated from a subset of 36 test locations derived from the 24plus(1-2) grid. Glaucoma severity was classified as PPG, early, moderate, or advanced based on MD. Differences between the full and reduced location sets were assessed using cluster-adjusted Bland-Altman analysis and linear mixed-effects models. Mixed-effects logistic regression was applied to estimate the probability of exceeding a prespecified operational MD-difference threshold (|ΔMD|> 1 dB), with patient-level bootstrap confidence intervals. RESULTS: The overall mean difference in recalculated MD was - 0.52 dB (95% limits of agreement: - 2.82 to 1.78 dB). The proportion of eyes with |ΔMD|> 1 dB was 1.9% in PPG, 17.8% in early glaucoma, 50.0% in moderate glaucoma, and 67.5% in advanced glaucoma. Worse MD was significantly associated with a higher probability of exceeding the prespecified operational MD-difference threshold (β = - 0.169; P < 0.001). MD values of - 5.4 dB (95% CI: - 7.0 to - 4.0) and - 11.9 dB (95% CI: - 14.1 to - 9.9) corresponded to 25% and 50% predicted probabilities of deviation, respectively. CONCLUSION: In this recalculation/subsampling analysis, 24plus(1)-derived MD was similar to 24plus(1-2)-derived MD in early glaucoma but diverged with advancing disease, particularly beyond approximately - 5 to - 6 dB, suggesting caution when interpreting 24plus(1)-derived MD in more advanced glaucoma.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compatibility of 24-2C central extra test points with OCT and OCTA parameters in early-stage glaucoma.International journal of ophthalmology · 2026
- Visual Field Indices or Retinal Nerve Fiber Layer? Predictors of Relative Afferent Pupillary Defect Severity in Asymmetric Glaucoma.Pakistan journal of medical sciences · 2026
- Macular Retinal Ganglion Cell Counts and Central Visual Field Sensitivity in Glaucoma: A Comparison of Logarithmic and Linear Scales.In vivo (Athens, Greece) · 2026
- Risk stratification of visual field progression in optic disc drusen with and without glaucoma.International ophthalmology · 2026
- Future visual field prediction in glaucoma: an application of first-order autoregressive approach.International ophthalmology · 2026
- Challenges in glaucoma diagnosis in small optic discs: An OCT-based analysis.Medicine · 2026