A novel technique of magnetically guided single-pass limbal extraction for intraocular foreign bodies: Eliminating the need for intraocular instrument relay.
Tingkun Shi, Yuqiang Huang, Honghe Xia, Chuang Jin, Xixuan Ke, Xulong Liao, Qi Zhang, Yinglin Cheng,
Joint Shantou International Eye Center, Shantou University & the Chinese University of Hong Kong, North Dongxia Road, Shantou, Guangdong, 515041, China. · Joint Shantou International Eye Center, Shantou University & the Chinese University of Hong Kong, North Dongxia Road, Shantou, Guangdong, 515041, China. haoyuchen@cuhk.edu.hk.
Key points
From the paper's conclusion- The magnetically guided single-pass limbal extraction technique represents a safe, effective, and streamlined approach for removing IOFBs in the setting of traumatic cataract.
Abstract
PURPOSE: To prospectively evaluate the safety and efficacy of a novel surgical technique for removing metallic intraocular foreign bodies (IOFBs) in eyes with concomitant traumatic cataract, utilizing a magnetic probe introduced through a limbal incision to directly extract the IOFB in a single pass. METHODS: This prospective, interventional case series included 21 consecutive eyes of 21 patients presenting with posterior segment IOFBs and traumatic cataracts. The standardized procedure involved: primary phacoemulsification, creation of a central posterior capsulotomy (posterior vitrectorhexis), pars plana vitrectomy (PPV) to mobilize the IOFB, and introduction of a 19-gauge intraocular magnet through the main limbal corneal incision. The magnet was passed through the posterior capsulotomy to directly engage and remove the IOFB via the same limbal route. Main outcome measures were successful IOFB removal, incidence of intraoperative complications (particularly IOFB slippage and iatrogenic retinal injury), postoperative complications, and best-corrected visual acuity (BCVA). RESULTS: The novel technique was successfully performed in all 21 eyes (100%) without the need for intraocular instrument relay. The mean IOFB size was 3.5 ± 1.6 mm. No cases of intraoperative IOFB slippage or iatrogenic retinal injury occurred. Preoperatively, 17 eyes (81.0%) had a BCVA worse than 20/200. Postoperatively, 17 eyes (81.0%) achieved a BCVA of 20/40 or better. No cases of postoperative retinal detachment or endophthalmitis were observed. Transient macular edema and epiretinal membrane occurred in one case each (4.8%). CONCLUSION: The magnetically guided single-pass limbal extraction technique represents a safe, effective, and streamlined approach for removing IOFBs in the setting of traumatic cataract.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Glass intraocular foreign body removal assisted by biological amniotic membrane: a case report.BMC ophthalmology · 2026
- Extracting the Unexpected: A 35-mm Curved Nail as an Intraocular Foreign Body.The American journal of case reports · 2026
- Silicone Oil-Assisted Removal of Large Intraocular Foreign Bodies.Retinal cases & brief reports · 2026
- Endoscopic techniques for removal of intraorbital foreign bodies - a clinical series.Acta neurochirurgica · 2026
- Navigation-Assisted Single-Incision Management of a Condylar Fracture With Foreign Bodies in the Condyle and Masseteric Space Following a Gunshot Wound.The Journal of craniofacial surgery · 2026
- Transorbital Penetrating Brain Injury Extending into the Prepontine Region: A Case Successfully Managed via Anterior Petrosectomy.NMC case report journal · 2026