International journal of legal medicine

Comparison of DNA recovery efficiency between variable cross-sectional biodegradable PLA fiber swab and conventional swabs on surface materials for forensic DNA trace evidence collection.

Chairat Manasatienkij, Aungkana Nimnual, Apirat Laobuthee, Kankavee Sukthavorn

Division of Pathology, Department of Medical Services, Rajavithi Hospital, Ministry of Public Health, Bangkok, 10800, Thailand. manasatienkij.c@gmail.com. · Division of Pathology, Department of Medical Services, Rajavithi Hospital, Ministry of Public Health, Bangkok, 10800, Thailand.

Observational

Key points

From the paper's conclusion
  • These findings indicate that cross-sectional fiber geometry is a meaningful design parameter for PLA swab performance, and that PLA(Plus) is a promising, biodegradable, locally manufacturable alternative to conventional swabs for forensic DNA trace evidence collection, warranting further multi-donor validation before adoption in casework.

Abstract

The shortage of imported forensic swabs during the COVID-19 pandemic prompted development of a locally producible alternative for crime-scene DNA collection. Swab tips were fabricated from biodegradable polylactic acid (PLA) fibers with four cross-sectional shapes (circle, worm, plus, star) and evaluated against three conventional swabs (cotton, foam, nylon flocked) for DNA collection from glass, steel, and electrical wire. A two-phase approach assessed release efficiency (%RE), collection efficiency (%CE), and overall recovery efficiency (%Recovery) by real-time PCR, followed by a touch DNA challenge with STR profiling. Flocked swabs showed the highest release efficiency (95.79 ± 5.54%), followed by foam (84.68 ± 22.23%) and PLA(Plus) (80.57 ± 14.00%), while PLA(Worm) and PLA(Circle) released significantly less DNA. Collection and recovery efficiency depended significantly on swab type by substrate interaction (two-way ANOVA, both p < .001): foam performed best on steel and glass, PLA(Circle) achieved the highest collection efficiency on wire, and cotton the highest recovery on wire. Overall recovery remained below 50% for all swabs, with PLA(Plus) most closely approaching cotton among the PLA designs. In the touch DNA challenge, 62.5% of samples yielded complete profiles; flocked and foam performed best (83.3% each), PLA(Plus) was intermediate (75.0%), and PLA(Worm) performed markedly worse (8.3%). These findings indicate that cross-sectional fiber geometry is a meaningful design parameter for PLA swab performance, and that PLA(Plus) is a promising, biodegradable, locally manufacturable alternative to conventional swabs for forensic DNA trace evidence collection, warranting further multi-donor validation before adoption in casework.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Comparison of DNA recovery efficiency between variable cross-sectional biodegradable PLA fiber swab and conventional swabs on surface materials for forensic DNA trace evidence collection — Science Skim