Comparison of DNA recovery efficiency between variable cross-sectional biodegradable PLA fiber swab and conventional swabs on surface materials for forensic DNA trace evidence collection.
Chairat Manasatienkij, Aungkana Nimnual, Apirat Laobuthee, Kankavee Sukthavorn
Division of Pathology, Department of Medical Services, Rajavithi Hospital, Ministry of Public Health, Bangkok, 10800, Thailand. manasatienkij.c@gmail.com. · Division of Pathology, Department of Medical Services, Rajavithi Hospital, Ministry of Public Health, Bangkok, 10800, Thailand.
Key points
From the paper's conclusion- These findings indicate that cross-sectional fiber geometry is a meaningful design parameter for PLA swab performance, and that PLA(Plus) is a promising, biodegradable, locally manufacturable alternative to conventional swabs for forensic DNA trace evidence collection, warranting further multi-donor validation before adoption in casework.
Abstract
The shortage of imported forensic swabs during the COVID-19 pandemic prompted development of a locally producible alternative for crime-scene DNA collection. Swab tips were fabricated from biodegradable polylactic acid (PLA) fibers with four cross-sectional shapes (circle, worm, plus, star) and evaluated against three conventional swabs (cotton, foam, nylon flocked) for DNA collection from glass, steel, and electrical wire. A two-phase approach assessed release efficiency (%RE), collection efficiency (%CE), and overall recovery efficiency (%Recovery) by real-time PCR, followed by a touch DNA challenge with STR profiling. Flocked swabs showed the highest release efficiency (95.79 ± 5.54%), followed by foam (84.68 ± 22.23%) and PLA(Plus) (80.57 ± 14.00%), while PLA(Worm) and PLA(Circle) released significantly less DNA. Collection and recovery efficiency depended significantly on swab type by substrate interaction (two-way ANOVA, both p < .001): foam performed best on steel and glass, PLA(Circle) achieved the highest collection efficiency on wire, and cotton the highest recovery on wire. Overall recovery remained below 50% for all swabs, with PLA(Plus) most closely approaching cotton among the PLA designs. In the touch DNA challenge, 62.5% of samples yielded complete profiles; flocked and foam performed best (83.3% each), PLA(Plus) was intermediate (75.0%), and PLA(Worm) performed markedly worse (8.3%). These findings indicate that cross-sectional fiber geometry is a meaningful design parameter for PLA swab performance, and that PLA(Plus) is a promising, biodegradable, locally manufacturable alternative to conventional swabs for forensic DNA trace evidence collection, warranting further multi-donor validation before adoption in casework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The comparison of excision, swabbing, tape-lifting, and scraping as techniques for DNA evidence recovery: A preliminary studyForensic Science International Synergy · 2026
- A quantitative evaluation of forensic sampling tools and extraction methodsJournal of Forensic Sciences · 2026
- Comparative evaluation of adhesive tapes and stamps for touch DNA collection from textile substrates.Journal of forensic sciences · 2026
- Methods matter: On the impact of non-transferential variables on reported data of studies on nucleic acid transfer, prevalence, persistence and recovery (TPPR).Forensic science international. Genetics · 2026
- Police field trial and exploratory laboratory optimization of the DNA-Buster.Science & justice : journal of the Forensic Science Society · 2026
- Understanding the mechanistic interaction between DNA and polystyrene microplastic and the effect of microplastic on forensic DNA analysis.International journal of legal medicine · 2026