Effects of routine laboratory parameter variations on diatom preservation: Implications for the standardization of forensic diatom testing.
Hao Qiu, Liuhong Yu, Meifang Yin, Yihua Zhao, Ling Zhou, Xiaodan He, Ping Huang, Ji Zhang
School of Forensic Medicine, Shanxi Medical University, Shanxi, China. · Fujian Chengyuan Judicial Identification Center, Fujian, China.
Key points
From the paper's conclusion- Our findings suggest that routine laboratory parameters should be incorporated into the standardization of forensic diatom testing, as their optimization can substantially improve diatom preservation.
Abstract
Forensic diatom testing remains controversial in drowning diagnosis and site inference, highlighting the need for standardized protocols. However, despite being involved in nearly all diatom testing methods, routine laboratory parameters have often been overlooked, and their effects on diatom preservation remain poorly investigated. This study systematically evaluated the effects of digestion parameters and washing procedure on diatom recovery and assemblage preservation, including digestion temperature and duration, centrifugation force and duration, washing frequency, and the residual pellet volume retained after each centrifugation. Controlled spiking experiments were performed using pooled natural water samples and human lung tissue. Procedural performance was assessed based on the diatom recovery rate and multiple assemblage-based indicators, including Bray-Curtis dissimilarity, Jaccard similarity, Spearman's rank correlation, and replicate dispersion. Both diatom recovery and assemblage integrity were better maintained under the selected combination of heating at ≤ 80 °C for ≤ 60 min, centrifugation at 3,000 rpm (1,313×g) for 5 min, and one washing cycle with 500 µL retained after centrifugation. Based on these parameters, we established an optimized extraction workflow that increased diatom recovery rates from 16.45% to 41.00% for acid digestion and from 80.87% to 84.42% for enzymatic digestion, while maintaining assemblage composition comparable to that of the reference water samples. Our findings suggest that routine laboratory parameters should be incorporated into the standardization of forensic diatom testing, as their optimization can substantially improve diatom preservation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Siliceous non-diatom microorganisms as complementary indicators in forensic investigations of drowning deaths.Legal medicine (Tokyo, Japan) · 2026
- Species discordance in diatom testing for drowning diagnosis: a biological passive sampling hypothesis with forensic implications.International journal of legal medicine · 2026
- Quantitative diatom analysis for drowning-site determination: Evaluation of accuracy and a practical decision guide.International journal of legal medicine · 2026
- Molecular Detection of Diatom DNA in Necrophagous Blow Fly Larvae (Chrysomya megacephala (Fabricius, 1794) (Diptera: Calliphoridae)): A PCR-HRM Proof-of-Concept Bridging Forensic Entomology and Diatomology.Insects · 2026
- Development of a novel universal primer set with high sensitivity and specificity for detection of diatom.Legal medicine (Tokyo, Japan) · 2026
- Study on the joint application of multi-database to improve the ability of high-throughput sequencing of forensic diatomsChina National GeneBank DataBase · 2026