Enhancing the therapeutic ratio in prostate LDR brachytherapy: A TOPAS Monte Carlo investigation of nanoparticle radiosensitization.
Shahab Atefi, Payman Rafiepour, Parvin Ahmadi
Department of Physics, University of Pavia, Pavia, Italy. Atefishahab@gmail.com. · School of Engineering, Persian Gulf University, Mahini Ave, Bushehr, 7516913817, Iran.
Key points
From the paper's conclusion- In conclusion, both Au and Pt NPs significantly enhance tumor dose in LDR brachytherapy while sparing adjacent organs, supporting an improved therapeutic ratio.
Abstract
This Monte Carlo study evaluates and compares the radiosensitization potential of gold (Au) and platinum (Pt) nanoparticles (NPs) in prostate low-dose-rate (LDR) brachytherapy using 125I and 103Pd sources. Using the TOPAS Monte Carlo software, Au and Pt NPs (30 and 100 nm) were uniformly distributed within a tumor volume at concentrations of 7, 18, and 30 mg/g within a modified MIRD male phantom. Dose enhancement factors (DEFs) and dose volume histograms (DVHs) were calculated for both source types. Au NPs consistently outperformed Pt NPs, with maximum DEFs of 2.58 for Au versus 2.53 for Pt (125I, 30 mg/g, 100 nm). DEF increased with concentration and NP size, with 125I yielding greater enhancement than 103Pd. This counterintuitive result, despite 103Pd's lower mean photon energy, is attributed to the more efficient escape of secondary electrons from the NPs and the higher fold-increase in photoelectric energy deposition relative to baseline for 125I. DVH analysis demonstrated selective tumor dose escalation (tumor Dmean increased from 239.8 Gy to 282.2 Gy for Pt with 103Pd) with negligible impact on organs at risk. Photoelectric energy deposition increased by up to 20.7-fold with NP addition, correlating with observed DEF trends. In conclusion, both Au and Pt NPs significantly enhance tumor dose in LDR brachytherapy while sparing adjacent organs, supporting an improved therapeutic ratio. The near-equivalence of Au and Pt NP performance suggests Pt may represent a viable, cost-effective alternative for clinical translation. These findings provide a dosimetric foundation for future experimental and clinical investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Context-Dependent Radioenhancement by Platinum Nanoparticles Under Conventional and Ultra-High Dose-Rate "FLASH" Radiotherapy.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Integrating Gold Nanoparticles with Brachytherapy: In Vitro Insights into Radiosensitization in Cervical Cancer.Cancers · 2026
- Radiosensitization effects of BaTiO₃ and gold nanoparticles in proton therapy of pancreatic tumors: A Monte Carlo study.Iranian journal of basic medical sciences · 2026
- Platinum Nanoparticle Radioenhancement is Preserved Under FLASH Very High-Energy Electron Irradiation: An in vitro Tumor Spheroid Study.International journal of nanomedicine · 2026
- Intratumoral 198Au Nanobrachytherapy Reduces Tumor Growth and Metastasis in a Murine Model of Triple-Negative Breast Cancer.ACS omega · 2026