European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery

Clinical use of acoustic immittance in Ménière's disease and endolymphatic hydrops: a systematic review of parameters and outcomes.

Şule Çekiç, Gülse Şeker, Elif Zehra Biber, Pınar Şahin, David Tomé, İsmail Cem Gülmez

Department of Audiology, Faculty of Health Sciences, Ankara Yıldırım Beyazıt University, Ankara, Türkiye. sulecekic@aybu.edu.tr. · Audiology MSc Program, Health Sciences Institute, Ankara Yıldırım Beyazıt University, Ankara, Türkiye.

Review

Key points

From the paper's conclusion
  • MFT and WBT can potentially provide valuable diagnostic information in MD or EH; increases in Y and G widths at 2 kHz with MFT, decreases in absorbance with WBT, and changes in RF have been reported, although it is recommended that these tests be supported by other diagnostic assessments.

Abstract

PURPOSE: Multiple acoustic techniques and devices have been used under acoustic-immittance measurements, including: single low-frequency, multifrequency (MFT), and wideband tympanometry (WBT). This study aims to systematically examine the utility, outcomes and efficacy of acoustic-immittance measurements in the diagnosis of endolymphatic hydrops (EH) and Meniere's disease (MD). METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Articles in English, without year restrictions but up to 2025, were included. The quality assessment of included studies was conducted. Methodology and results were assessed. RESULTS: A total of 1560 articles were identified, and 18 articles were included. The most frequently used test was MFT, although traditional 226 Hz tympanometry, WBT, and Eustachian tube function tests were also utilized. Traditional 226 Hz tympanometry was generally within normal pressure limits in MD, while more negative compared to controls. Using MFT, peak widths at 2 kHz were primarily evaluated; in the MD and EH groups, both Y and G widths were occasionally increased, although some studies reported no significant differences. A significant decrease in absorbance of MD and EH was indicated, studies with contrary findings have also been reported. In many studies, resonance frequency (RF) changed in the negative direction. CONCLUSIONS: MFT and WBT can potentially provide valuable diagnostic information in MD or EH; increases in Y and G widths at 2 kHz with MFT, decreases in absorbance with WBT, and changes in RF have been reported, although it is recommended that these tests be supported by other diagnostic assessments.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers