Fewer poor joint awareness results with cementless TKA compared with the same-design cemented implant.
Luca De Berardinis, Filippo Leggieri, Paolo Salari, Giuseppe Polizzotti, Andrea Baldini
Orthopaedic and Trauma Unit, IRCCS Ospedale San Raffaele, Milan, Italy. · University of Florence, Florence, Italy. filippo.leggieri@unifi.it.
Key points
From the paper's conclusion- The 3D-printed full-titanium cementless TKA did not produce a significantly higher mean FJS-12 than the same-design cemented device at 24 months, but it significantly reduced the proportion of patients with poor joint awareness outcomes.
Abstract
BACKGROUND: Comparisons of cemented and cementless TKA have focused on mean outcomes and generally reported equivalence. We hypothesized that a 3D-printed full-titanium cementless TKA and the same-design cemented implant would not differ significantly in average joint awareness but would differ in the proportion of patients with the poorest results, and we compared the two both at the mean and across the outcome distribution. METHODS: Prospective two-cohort study of 109 primary unilateral TKAs (54 cementless, 55 cemented) for end-stage knee osteoarthritis, with complete 24-month follow-up. Exclusion criteria were valgus deformity and bilateral surgery. The primary outcome was the FJS-12, analysed both at the mean (multivariable linear regression, with propensity score overlap weighting as sensitivity analysis) and across its distribution (quantile regression). Secondary outcomes were PASS achievement (FJS-12 ≥ 33.3), OKS, and time to functional satisfaction. RESULTS: The cementless group was younger (P < 0.001) with more men (P = 0.008). Mean FJS-12 was not different between groups after adjustment (β = 7.4, 95% CI - 1.8 to 16.6, P = 0.115), although the confidence interval did not exclude a difference exceeding the minimal clinically important difference; this finding was reproduced by overlap weighting. On quantile regression, cementless patients scored significantly higher at the 10th and 25th percentiles (adjusted P = 0.028 and 0.021) but not at the median or above. A greater proportion of cementless patients achieved the PASS (96.3% vs. 76.4%; absolute difference 19.9%, 95% CI 7.1 to 32.9; number needed to treat 5), which persisted after adjustment (P = 0.005). No significant differences were observed in OKS (P = 0.91) or time to functional satisfaction (adjusted P = 0.39). No revisions or loosening occurred. CONCLUSION: The 3D-printed full-titanium cementless TKA did not produce a significantly higher mean FJS-12 than the same-design cemented device at 24 months, but it significantly reduced the proportion of patients with poor joint awareness outcomes. LEVEL OF EVIDENCE: III.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Revision Rates and Clinical Outcomes of Two Cementless Cruciate-Retaining Total Knee Arthroplasty Designs at Two-Year Follow-Up: A Propensity Score-Adjusted Comparative Analysis.Medicina (Kaunas, Lithuania) · 2026
- The Rapid Rise of Cementless Total Knee Arthroplasty in Canada.The Journal of arthroplasty · 2026
- Radiological and clinical outcomes of cementless versus cemented implants in total knee arthroplastyThe Bone & Joint Journal · 2025
- Cemented Versus Cementless Fixation in Primary Total Knee Arthroplasty: A Systematic Review and Narrative Synthesis of Randomized Controlled Trials.Journal of clinical medicine · 2026
- Comparable Early Outcomes Between Cemented and Cementless MAKO Functional Alignment Total Knee Arthroplasty: A Propensity-Matched Analysis.Journal of orthopaedics · 2026
- Superior Sensitivity of the Forgotten Joint Score in Total Knee Arthroplasty: A Meta-Analysis of Randomized Controlled Trials.Arthroplasty today · 2026