Key points
From the paper's conclusion- Partial triceps tendon transfer improved dynamic elbow stabilization and significantly reduced PLRI in a LCLC‑deficient in vitro model. However, it did not fully restore joint stability, supporting its role as a potential adjunct or salvage option rather than a primary procedure. The findings highlight the importance of dynamic muscle tension in lateral elbow stability, while the time‑zero, in vitro design limits direct clinical translation and warrants further in vivo investigations.
Abstract
PURPOSE: Posterolateral rotatory instability (PLRI) of the elbow results from lateral collateral ligament complex (LCLC) insufficiency. In the setting of failed conventional ligament reconstruction, no established salvage procedure is available. This study biomechanically evaluated partial triceps tendon transfer to the supinator crest as a dynamic stabilization concept for PLRI. METHODS: Nine fresh-frozen human elbow specimens underwent cyclic external rotational loading of 0.5 Nm. Specimens were tested sequentially in the native state, an LCLC/common extensor origin-deficient unstable state, after transosseous LCLC repair, and after partial triceps tendon transfer to the supinator crest with the LCLC detached. Testing was performed under combined biceps/triceps loading conditions with external forearm rotation relative to the humerus as the primary outcome. A two-factor repeated-measures analysis of variance (RM-ANOVA) compared unstable, repaired, and tendon-transfer conditions across loading conditions. The native state was assessed unloaded and reported separately in a one-factor RM-ANOVA. RESULTS: Intervention significantly affected external rotation (F(2,16) = 33.31, p < 0.001, η2p = 0.81). Across loading conditions, partial triceps transfer significantly reduced external rotation compared to the unstable state (mean difference [MD]=-3.38°, p = 0.005), while LCLC repair showed lower external rotation than triceps tendon transfer (MD=-3.13°, p = 0.012). External rotation also differed significantly across the combined biceps/triceps loading conditions (Greenhouse-Geisser corrected F(1.26,10.11) = 77.00, p < 0.001, η2p = 0.91), decreasing from 13.37° at 0 kg biceps/0 kg triceps to 2.42° at 0.5 kg biceps/4.0 kg triceps. CONCLUSION: Partial triceps tendon transfer improved dynamic elbow stabilization and significantly reduced PLRI in a LCLC‑deficient in vitro model. However, it did not fully restore joint stability, supporting its role as a potential adjunct or salvage option rather than a primary procedure. The findings highlight the importance of dynamic muscle tension in lateral elbow stability, while the time‑zero, in vitro design limits direct clinical translation and warrants further in vivo investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Is biceps augmentation effective for scope-assisted lower trapezius tendon transfer in posterosuperior irreparable rotator cuff tears? A retrospective short-term clinical comparisonArchives of Orthopaedic and Trauma Surgery · 2026
- Arthroscopically assisted lower trapezius transfer using a peroneus longus autograft for massive irreparable posterosuperior rotator cuff tears: Minimum 2-year clinical and radiological outcomes.Journal of experimental orthopaedics · 2026
- Arthroscopic-Assisted Lower Trapezius Transfer Improves Outcomes in Patients With Irreparable Posterosuperior Rotator Cuff Tears Irrespective of the Presence of External Rotation Lag Sign.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- The Stiff Elbow Revisited: How Much Motion Can Surgery Really Restore?Medicina (Kaunas, Lithuania) · 2026
- Endoscopic Peroneus Longus Transfer for Chronic Achilles Tendon Rupture: A Novel Surgical Technique.Foot & ankle specialist · 2026
- Use of a Bio-Inductive Collagen Implant in Distal Triceps Tendon Repair: A Case Report.Cureus · 2026