Routine versus selective use of a femoral protection wire in transfemoral TAVI: a single-centre analysis of vascular complications.
Marc Adrian Rogmann, Victor Klingemann, Max Meertens, Majid Ahoopai, Karl-Philipp Rommel, Philipp Lurz, Ralph S von Bardeleben, Martin Geyer
Department for Cardiology, University Medical Centre of the Johannes Gutenberg University, Langenbeckstraße 1, 55131, Mainz, Germany. · Department for Cardiology, University Medical Centre of the Johannes Gutenberg University, Mainz, Germany.
Key points
From the paper's conclusion- In contemporary transfemoral TAVI, routine protection wire use was not associated with reduced major vascular complications and was linked to a higher rate of minor access site injuries. These findings support a restrictive rather than routine use of protection wires in current practice.
Abstract
BACKGROUND: Transfemoral transcatheter aortic valve implantation (TAVI) is the treatment of choice for severe aortic stenosis in patients with elevated surgical risk. However, vascular complications remain a major source of morbidity and mortality. The protection wire technique was introduced to prevent major access-related complications, but its role in contemporary TAVI practice is uncertain. AIMS: To evaluate whether routine protection wire use reduces vascular complications in contemporary transfemoral TAVI. METHODS: We performed a retrospective, single-centre analysis of 1476 consecutive patients undergoing transfemoral TAVI between January 2020 and August 2023. Until November 2021, protection wire placement was standard-of-care (Group 1, n = 801); thereafter procedures were performed without routine protection wire use (Group 2, n = 675). Vascular complications were defined according to VARC-3 criteria. Multivariable logistic regression was used to identify independent predictors of minor and major vascular complications. RESULTS: The composite of minor and major vascular complications occurred more frequently in Group 1 than in Group 2 (18.6% vs. 10.8%, p < 0.001). In Group 1, 34.8% of access-related complications were associated with the protection wire access. Major vascular complications were numerically less frequent in Group 2 (2.5% vs. 4.2%). Omission of routine protection wire placement was independently associated with a lower risk (OR 0.52, 95% CI 0.38-0.72, p < 0.001). CONCLUSION: In contemporary transfemoral TAVI, routine protection wire use was not associated with reduced major vascular complications and was linked to a higher rate of minor access site injuries. These findings support a restrictive rather than routine use of protection wires in current practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety of Selective and Routine Femoral Access Angiography Post-Transcatheter Aortic Valve Implantation.JACC. Advances · 2026
- Rethinking access in TAVI: large multicenter cohort-based evaluation of a single access approach compared with standard bi-femoral strategyEuropean Heart Journal · 2026
- Eliminating transvenous right ventricular leads reduces pacing-related cardiac tamponade during TAVI: a mechanistic meta-analysisEuropean Heart Journal · 2026
- Comparison of Two Percutaneous Femoral Closure Strategies During Transcatheter Aortic Valve Implantation.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Single vs Double ProGlide Devices for Access Site Closure after Transfemoral Aortic Valve Replacement: The SINGLE-CLOSURE Trial.Journal of the American College of Cardiology · 2026
- Outcomes of left ventricular pacing with a pre-shaped guidewire during transcatheter aortic valve implantation.REC, interventional cardiology · 2026