Predictors of echocardiographic response in the Budapest-CRT upgrade trial.
Eperke Merkel, Richárd Masszi, Bálint Lakatos, Robert Hatala, Boglárka Veres, Alexandra Fábián, István Osztheimer, László Gellér,
Semmelweis University, Heart and Vascular Center, Budapest, Hungary. · Department of Cardiology and Angiology, National Institute of Cardiovascular Diseases and Slovak Medical University, Bratislava, Slovakia.
Key points
From the paper's conclusion- In patients with pacing-induced cardiomyopathy, CRT-D upgrade significantly improved echocardiographic outcomes. Non-ischemic etiology, higher RV pacing burden, and lateral LV lead positioning were associated with greater benefit. These results underscore the importance of tailored patient selection and lead placement strategies to optimize CRT-D upgrade outcomes.
Abstract
BACKGROUND AND AIMS: Up to 30% of patients fail to respond after cardiac resynchronization therapy (CRT). While echocardiographic predictors of response are well described in de novo CRT, evidence in CRT upgrade populations remains limited. We investigated predictors of echocardiographic response in the BUDAPEST-CRT Upgrade trial cohort. METHODS: In this randomized trial, 360 patients with heart failure and reduced ejection fraction (HFrEF) with priorly implanted pacemaker or ICD, ≥ 20% right ventricular (RV) pacing burden, and wide-paced QRS (≥ 150 ms) were randomized to CRT-D upgrade (n = 215) or ICD upgrade (n = 145). Echocardiographic response was defined as ≥ 15% reduction in left ventricular end-systolic volume (LVESV) at 12 months. RESULTS: Among 275 patients with paired echocardiographic data, 161 (59%) were responders. Responders had fewer HF hospitalizations (0.6% vs. 7.0%, p = 0.003), more often received mineralocorticoid receptor antagonists (71% vs. 59%, p = 0.038), and showed a higher baseline RV pacing burden (88.9% vs. 83.4%, p = 0.025) than non-responders. Independent predictors of echocardiographic response were randomization to CRT-D (OR 5.57, 95% CI 2.56-12.12, p < 0.0001), greater RV pacing burden (OR 1.02 per %, 95% CI 1.00-1.04, p = 0.024), non-ischemic cardiomyopathy (OR 2.50, 95% CI 1.15-5.26, p = 0.021), and a lateral LV lead position (OR 8.79, 95% CI 1.28-60.39, p = 0.027). CONCLUSIONS: In patients with pacing-induced cardiomyopathy, CRT-D upgrade significantly improved echocardiographic outcomes. Non-ischemic etiology, higher RV pacing burden, and lateral LV lead positioning were associated with greater benefit. These results underscore the importance of tailored patient selection and lead placement strategies to optimize CRT-D upgrade outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Redefining response to Cardiac Resynchronisation Therapy: A Post-hoc Analysis of the MORE-CRT MPP trial.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Predicting Persistent Left Ventricular Dysfunction After Cardiac Resynchronization Therapy Upgrade in Pacing-Induced Cardiomyopathy.Journal of clinical medicine · 2026
- Pre-Implant Substrate, Peri-Implant Electrical Features, and Outcomes Across Four Echocardiographic Phenotypes After CRT-D.Journal of clinical medicine · 2026
- Predictors of Favourable Response to Cardiac Resynchronization Therapy in Patients with Heart Failure with Reduced Ejection Fraction: A Narrative Review.Biomedicines · 2026
- Conduction system pacing as a primary strategy for cardiac resynchronization therapy in reduced ejection fraction: An updated systematic review and meta-analysis of randomized controlled trialswe.Progress in cardiovascular diseases · 2026
- Left bundle branch area vs biventricular pacing for cardiac resynchronization therapy: the LEFT-BUNDLE-CRT trialEuropean Heart Journal · 2026