科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Clinical Research in Cardiology2026-05-18· Medicine

Impact of lipoprotein(a) on the durability of aortic bioprosthetic valves

Finn Syryca, Johannes Krefting, Elisabeth Oertel, Felix Wirth, Costanza Pellegrini, T Rheude, N. Patrick Mayr, Stefan Holdenrieder, Hector A. Alvarez-Covarrubias, Moritz von Scheidt, Thorsten Kessler, Hendrik B. Sager, Heribert Schunkert, A Kastrati, W Koenig, Magdalena Erlebach, Erion Xhepa, Hendrik Ruge, Michael Joner, Markus Krane, Teresa Trenkwalder

原始摘要(英文原文)· Original abstract
BACKGROUND: The expanding use of bioprosthetic aortic valve replacements has raised concerns regarding the long-term durability of bioprosthetic valve prostheses. While lipoprotein(a) [Lp(a)] is implicated in the pathogenesis of native aortic valve stenosis, its impact on bioprosthetic valve degeneration leading to reintervention remains unclear. OBJECTIVE: To evaluate the association between Lp(a) levels and structural degeneration of aortic bioprosthetic valves in patients undergoing secondary aortic valve procedure. METHODS: We retrospectively analyzed 389 patients with available Lp(a) values who underwent replacement of a degenerated aortic bioprosthetic valves between February 2001 and September 2024. Endpoint was the interval from initial surgical aortic valve replacement (SAVR) to the second aortic valve procedure either as transvascular or surgical replacement. Patients were stratified by Lp(a) levels into low (< 105 nmol/L) and high (≥ 105 nmol/L) Lp(a) groups. Associations between Lp(a) levels and time-to-reintervention were assessed using Kaplan-Meier survival analysis. RESULTS: Out of an initial cohort of 909 patients, 389 met the inclusion criteria. Of these, 296 patients showed low and 93 high Lp(a) levels. Baseline characteristics were comparable between both groups. The median time from initial valve implantation to the second aortic valve intervention did not differ significantly by Lp(a) group. Kaplan-Meier analysis demonstrated no significant association between elevated Lp(a) and time-to-reintervention (hazard ratio [HR] 0.81; 95% confidence interval [CI] 0.58 - 1.13; p = 0.215). CONCLUSIONS: In this cohort of patients undergoing secondary aortic valve procedure, elevated Lp(a) levels were not associated with earlier need for reintervention. Unlike in native aortic stenosis, our findings do not support a clinically meaningful role for Lp(a) in bioprosthetic aortic valve degeneration.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Impact of lipoprotein(a) on the durability of aortic bioprosthetic valves — 科研速览 Science Skim