Effectiveness of ultrasound-guided hydrostatic versus fluoroscopy-guided air reduction for pediatric intussusception: a severity-adjusted cohort analysis.
Ahmed Abdelmohsen
Department of Pediatric Surgery, Faculty of Medicine, Al-Azhar University, Cairo, Egypt. a.abdelmohsen@azhar.edu.eg.
Key points
From the paper's conclusion- After adjusting for disease severity, UGHR and FGAR show equivalent effectiveness and safety. Crude differences reflect more severe presentations in the UGHR group. Severity markers-including symptom duration, trapped fluid, and intussusceptum length-are strong predictors of failure and should guide clinical decision-making.
Abstract
BACKGROUND: The comparative effectiveness of fluoroscopy-guided air reduction (FGAR) versus ultrasound-guided hydrostatic reduction (UGHR) for pediatric intussusception remains uncertain, especially when clinical and sonographic severity are considered. OBJECTIVE: To compare the effectiveness and safety of FGAR and UGHR after adjusting for disease severity and to identify independent predictors of non-operative reduction failure. METHODS: A retrospective cohort of 192 children (0-24 months) with ileocolic intussusception treated between 2018 and 2024 was analyzed. Baseline clinical variables and ultrasound markers were collected. Multivariable logistic regression, adjusting for clinical and sonographic severity markers (symptom duration, anal protruding mass, intussusceptum length, and trapped fluid), identified predictors of failure, with model performance assessed using the area under the ROC curve. RESULTS: Children undergoing UGHR presented with more severe disease, including longer symptom duration (34 vs. 22 h; p = 0.01), higher delayed presentation > 48 h (32.1% vs. 15.0%; p = 0.004), and more trapped fluid (30.4% vs. 16.3%; p = 0.02). Initial success was 86.3% for FGAR and 77.7% for UGHR (p = 0.12); however, the UGHR group had significantly more trapped fluid and longer symptom duration at baseline. After adjustment for these and other severity markers, technique was not associated with failure (aOR 1.22, 95% CI 0.64-2.28; p = 0.54). Independent predictors included longer symptom duration (aOR 1.27 per 12 h; p < 0.001), anal protruding mass (aOR 3.58; p = 0.01), greater intussusceptum length (aOR 1.41 per cm; p < 0.001), and trapped fluid (aOR 3.47; p < 0.001). Model discrimination was excellent (AUC 0.85). Perforation rates were similarly low (1.3% FGAR vs. 0.9% UGHR). CONCLUSION: After adjusting for disease severity, UGHR and FGAR show equivalent effectiveness and safety. Crude differences reflect more severe presentations in the UGHR group. Severity markers-including symptom duration, trapped fluid, and intussusceptum length-are strong predictors of failure and should guide clinical decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound-guided hydrostatic enema reduction for intussusception in children younger than 12 months: a systematic review and meta-analysisPediatric Surgery International · 2026
- Ultrasonographic findings at the end of failed hydrostatic reduction in pediatric intussusception: focus on the frond sign and immobility.Pediatric radiology · 2026
- Ultrasound-guided hydrostatic reduction of intussusception: a practical guide with a focus on low-resource settings.Emergency radiology · 2026
- Hydrostatic Reduction of Intussusception under Ultrasound Guidance: An Initial Experience in a Developing CountryAfrican Journal of Paediatric Surgery · 2026
- Predicting the need for surgery in children undergoing enema reduction for intussusception: development and internal-external validation in a 10-year cohort.European journal of pediatrics · 2026
- Non-Operative Reduction of Childhood Intussusception in Low- and Middle-Income Countries: A Review of Techniques, Outcomes, and Emerging Challenges.Nigerian medical journal : journal of the Nigeria Medical Association · 2026