Bedside external ventricular drainage in the NICU: procedural efficiency and infection trends in a 15-year single-center cohort.
Taehoon Kim, Seung-Ki Kim, Joo Whan Kim, Seh Hyun Kim, Ju Sun Heo, Baek Sup Shin, Seung Han Shin, Ee-Kyung Kim,
Division of Pediatric Neurosurgery, Seoul National University Children's Hospital, Seoul, Republic of Korea. · Division of Neonatology, Department of Pediatrics, Seoul National University Children's Hospital, Seoul, Republic of Korea.
Key points
From the paper's conclusion- Bedside NICU EVD insertion was substantially faster than operating-room insertion after adjustment for case-mix differences. Culture-positive infections occurred only during bedside catheter episodes; therefore, infection findings should be interpreted descriptively rather than as evidence of comparative infection safety.
Abstract
PURPOSE: To compare the procedural efficiency of bedside versus operating-room external ventricular drainage (EVD) insertion in a neonatal intensive care unit (NICU) and to describe culture-positive EVD-associated infections. METHODS: We performed a retrospective single-center cohort study of NICU infants who underwent EVD insertion between 2011 and 2025. Operative time and insertion characteristics were analyzed at the insertion level. Culture-positive EVD-associated infections acquired at the study hospital were described, and annual infection incidence was explored in relation to unit methicillin-resistant Staphylococcus aureus (MRSA) acquisition rates. RESULTS: Sixty-six infants underwent 161 EVD insertions (115 bedside, 28 operating room, 18 outside hospital). Among 140 study-hospital insertions with documented operative time, bedside insertion was faster than operating-room insertion (24.5 (11.4) vs 57.4 (35.2) min; adjusted difference, 32.5 min; 95% CI, 16.7-48.4; p < 0.001). Seven study-hospital-acquired culture-positive EVD-associated infections occurred (2.37 per 1000 catheter-days at risk), all during bedside catheter episodes. Median time from catheter insertion to first positive culture was 2 days. In an exploratory annual ecological analysis, infection incidence correlated with NICU MRSA acquisition rates (Pearson r = 0.74; p = 0.009). CONCLUSION: Bedside NICU EVD insertion was substantially faster than operating-room insertion after adjustment for case-mix differences. Culture-positive infections occurred only during bedside catheter episodes; therefore, infection findings should be interpreted descriptively rather than as evidence of comparative infection safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative epidemiology and outcomes of gram-negative and non-gram-negative External Ventricular Drain (EVD)-related infections: a 10-year single-center cohort study.Neurosurgical review · 2026
- Complication profile of two surgical techniques, neurosurgical experience, and operative setting for pediatric external ventricular drainage implantation.Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 2026
- Risk factors for nosocomial meningitis in patients with external ventricular drainagesJournal of Intensive Care · 2025
- Ventriculostomy-associated infection rates and routine EVD replacement: a systematic review and meta-analysis.British journal of neurosurgery · 2026
- Impact of initial disease severity and metabolic stress on mortality in patients with suspected external ventricular drain-associated infection.Neurosurgical review · 2026
- Incidence, risk factors, and microbial spectrum of external ventricular drain-related infections among adult neurocritical care patients: A systematic review and meta-analysis.Journal of the Intensive Care Society · 2026