Too good to be true? AI performance in CT-based urinary stone detection and classification: EAU endourology systematic review and diagnostic accuracy meta-analysis.
Ali Talyshinskii, Lazaros Tzelves, Vineet Gauhar, Carlotta Nedbal, Ivan Gorgotsky, Nariman Gadzhiev, Vigen Malkhasyan, Danielle Castellani,
Department of Urology and Andrology, Genome Clinic, Astana, Kazakhstan. ali-ma@mail.ru. · Department of Urology, Sismanogleio Hospital, National and Kapodistrian University of Athens, Athens, Greece.
Key points
From the paper's conclusion- Substantial methodological heterogeneity and high risk of bias limit clinical generalizability. Detection studies better reflect real-world workflows and show lower performance. Current evidence does not support routine clinical implementation without standardized reporting and robust external validation.
Abstract
PURPOSE: To evaluate pooled performance of artificial intelligence (AI) in computed tomography (CT)-based urinary stone detection and classification and identify methodological factors influencing results. METHODS: This review was registered in PROSPERO (CRD420261319940). A systematic search of PubMed, Cochrane Library, and Google Scholar was conducted up to March 15, 2026. Studies evaluating AI-based detection or classification of urolithiasis on CT with available validation/test cohort data (sensitivity/specificity or 2 × 2 tables) were included. A bivariate random-effects model generated pooled sensitivity, specificity, and hierarchical summary receiver operating characteristic (HSROC) curves. Meta-regression explored moderators related to dataset composition and AI pipelines. Risk of bias was assessed using QUADAS-AI. RESULTS: 14 studies (five detection-based, nine classification-based) were included. Overall pooled sensitivity and specificity were 0.967 and 0.979 (AUC 0.987). Classification studies demonstrated higher pooled sensitivity (0.977) and specificity (0.990) compared with detection studies (0.935 and 0.919; AUC 0.945). Significant heterogeneity was observed and influenced by training sample size, class imbalance, presence of bladder stones or other pathologies, and architectural choices. Most studies had high risk of bias, lacked external validation, and frequently used slice-level or pre-selected datasets, potentially overestimating performance. CONCLUSION: Substantial methodological heterogeneity and high risk of bias limit clinical generalizability. Detection studies better reflect real-world workflows and show lower performance. Current evidence does not support routine clinical implementation without standardized reporting and robust external validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Determination of urinary stone composition using computed tomography using artificial intelligence.Central European journal of urology · 2026
- The role of artificial intelligence in urological malignancies: an overview of systematic reviews.The Canadian journal of urology · 2026
- Enhancing renal stone detection through artificial intelligence models.Frontiers in medicine · 2026
- Study of bladder cancer detection in standard white light versus AI-supported endoscopy-01 (RAISE-01) – Development and validation of an AI-based support toolInternational Journal of Medical Informatics · 2026
- A Validated Artificial Intelligence Model Versus Urinary Supersaturation Alone for Predicting Kidney Stone Composition.Mayo Clinic proceedings · 2026
- Artificial intelligence advances in cystoscopy and imaging for bladder cancer: a narrative review.The Canadian journal of urology · 2026