From the paper's conclusion- The VOID model demonstrated only fair discrimination and suboptimal calibration, precluding immediate clinical use without prior recalibration. Beyond methodological limitations, these findings suggest that underperformance may reflect the inherent constraints of a purely clinicourodynamic paradigm, underscoring the need for conceptually refined models integrating broader determinants of SNM response.
Abstract
PURPOSE: A multivariable predictive model for sacral neuromodulation (SNM) success in non-obstructive urinary retention and/or slow urinary stream (NOUR/SS), named VOID, was recently developed and internally validated. We aimed to externally validate this model. METHODS: This retrospective multicenter study included all patients undergoing a two-stage SNM for NOUR/SS between 2018 and 2025 across 7 academic centers. The primary outcome was defined as the permanent implantation rate. Secondary outcomes included changes in bladder voiding parameters. Model performance was assessed through discrimination (area under the curve [AUC]), calibration (graphical assessment), and overall performance (Brier score). RESULTS: Of 239 patients included, 152 (63.6%) underwent permanent implantation. The model showed fair discrimination (AUC = 0.627) and poor overall accuracy (Brier score = 0.221). Calibration analysis indicated imperfect agreement between predicted and observed probabilities. Among the original predictors, only female sex remained independently associated with implantation (OR 2.08, 95% CI 1.14-3.79; p = 0.017), while age ≤ 52 years showed a non-significant trend (p = 0.074). Maximal urethral closure pressure ≥ 70 cmH₂O and absence of neurological disease affecting the lower motor neuron were not associated with the outcome. The retrospective design and heterogeneity across centers represent the main limitations. CONCLUSIONS: The VOID model demonstrated only fair discrimination and suboptimal calibration, precluding immediate clinical use without prior recalibration. Beyond methodological limitations, these findings suggest that underperformance may reflect the inherent constraints of a purely clinicourodynamic paradigm, underscoring the need for conceptually refined models integrating broader determinants of SNM response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Revision and Explantation After Permanent Sacral Neuromodulation for Overactive Bladder: A Systematic Review and Meta-Analysis.International urogynecology journal · 2026
- Effect of Sacral Neuromodulation in Women with Prior Pelvic Floor Surgery: A Systematic Review of the Literature.International urogynecology journal · 2026
- Development and Validation of a Nomogram for Predicting Postoperative Urinary Retention After Pelvic Floor SurgeryHealthcare · 2026
- A Simple Prognostic Score for Malignant Ureteral Obstruction: Development and Temporal Validation.Current oncology (Toronto, Ont.) · 2026
- Development of a risk prediction model for acute urinary retention after interventional procedures incorporating perioperative nursing-related factors.The French journal of urology · 2026
- Developing a Risk-Adjustment Model for Stress Urinary Incontinence Procedures Using Australasian Pelvic Floor Procedure Registry Data.International urogynecology journal · 2026