科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ World journal of urology2026-09-22

Rethinking high-frequency lithotripsy: a review by EAU endourology group.

Anil Shrestha, Akash Chitrakar, Jia-Lun Kwok, Mariela Corrales, Alba Sierra, Eugenio Ventimiglia, Ben Chew, Esteban Emiliani, Etienne Xavier Keller, Frederic Panthier, Vincent De Coninck, Bhaskar Somani, Olivier Traxer

一句话结论 · In one sentence

HF and LF settings achieved comparable SFR and operative times. The overall incidence of ureteral injury across both frequency ranges was low. However, higher instances of ureteral injury and infection were observed in studies where HF settings were used in combination with HP. Bleeding complications were found to be related to laser technology rather than frequency.

原始摘要(英文原文)· Original abstract
PURPOSE: To evaluate the current evidence comparing high-frequency (HF) (> 20 Hz) versus low-frequency (LF) (≤ 20 Hz) laser lithotripsy in patients undergoing flexible and/or rigid ureteroscopy for renal and ureteral stones, with focus on stone-free rate (SFR), operative outcomes, and safety profiles. METHODS: A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A search was conducted on MEDLINE and EMBASE databases through October 2025 for randomized controlled trials (RCT), prospective comparative studies, and single-arm studies involving patients undergoing ureteroscopic laser lithotripsy with holmium: yttrium aluminum-garnet (Ho: YAG), thulium fiber lasers (TFL), and pulsed Thulium: YAG (p-Tm: YAG) lasers. Primary outcomes included SFR, and secondary outcomes included operative duration, energy utilization, and complications. RESULTS: Twenty-two studies encompassing 2,059 patients were included. SFR demonstrated substantial overlap between LF (67-100%) and HF (77-100%) groups. Operative times ranged from 24.7 to 96.6 min for LF and 19.9-90 min for HF settings. Energy consumption (J/mm³) showed similar ranges: 8.7-29.03 J/mm³ for LF and 1.6-27.9 J/mm³ for HF groups. Overall complication rates remained low (4-21%). Notably, studies using TFL combining HF with high-power (HP) settings for renal stones reported elevated ureteral injury rates (3.1-4.4%). Infectious complications demonstrated frequency-dependent patterns, with HF, HP Ho: YAG settings showing UTI/sepsis rates up to 2.9% in patients with large stones. Bleeding complications appeared more strongly associated with laser technology than frequency settings, with intra-op bleeding occurring more with use of Ho: YAG laser and post-op hematuria occurring more with TFL use. CONCLUSION: HF and LF settings achieved comparable SFR and operative times. The overall incidence of ureteral injury across both frequency ranges was low. However, higher instances of ureteral injury and infection were observed in studies where HF settings were used in combination with HP. Bleeding complications were found to be related to laser technology rather than frequency.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Rethinking high-frequency lithotripsy: a review by EAU endourology group. — 科研速览 Science Skim