European radiology

Deep learning-based segmentation of the ischemic core and severe hypodensity on noncontrast head CT compared with CT perfusion and diffusion-weighted imaging.

Henk van Voorst, Bin Jiang, Praneeta Konduri, Adrien Ter Schiphorst, Aroosa Zamarud, Seena Dehkharghani, Lieselotte vandeWalle, Ewout Heylen,

Department of Radiology, Stanford School of Medicine, Stanford, CA, USA. hvv@stanford.edu. · Department of Radiology, Stanford School of Medicine, Stanford, CA, USA.

Computational

Key points

From the paper's conclusion
  • Spatial and biomarker agreement between DLNCCT and DWI was suboptimal but comparable to CTP-DWI. Nevertheless, DLNCCT-derived average lesion density and hypodense volume were associated with functional outcomes.

Abstract

OBJECTIVES: To compare the spatial overlap, imaging marker agreement, and outcome associations of acute ischemic regions of interest (ROIs) using deep-learning NCCT (DLNCCT) versus manual NCCT, CTP, and DWI-based segmentations. MATERIALS AND METHODS: We trained a deep learning model to segment ischemic ROIs on admission NCCT (DLNCCT). DLNCCT was compared with manual NCCT, CTP (rCBF < 30%/38%), and DWI using the Dice similarity coefficient (mean ± SD), Bland-Altman analysis (mean difference [95% CI]), and concordance correlation coefficient (CCC). For each ROI, we compared NCCT imaging biomarkers: average lesion density (HU); modified net water uptake (mNWU in %); total volume (mL); and hypodense (≤ 26 HU) volume (mL). DLNCCT biomarkers were associated with reversed 90-day ordinal modified Rankin Scale (genOR [95% CI]). RESULTS: We used 218/762 train/test cases. Dice was 0.30 ± 0.30 between DLNCCT and manual segmentation, 0.22 ± 0.25 between DLNCCT-DWI, and 0.15 ± 0.22/0.21 ± 0.24 between CTP (rCBF < 30%/< 38%)-DWI. DLNCCT-DWI biomarker agreement was -1 HU (95% CI: -7; 6) for average density (CCC: 0.71), 4.9% (95% CI: -7.0; 16.8) for mNWU (CCC: 0.35), -16 mL (95% CI: -108; 76) for total volume (CCC: 0.57), and -4 mL (95% CI: -31; 23) for hypodense lesion volume (CCC: 0.75). Average lesion density (1.11 [95% CI: 1.06; 1.16]) and hypodense volume (0.85 [95% CI: 0.72; 0.99]) were associated with 90-day mRS. CONCLUSION: Spatial and biomarker agreement between DLNCCT and DWI was suboptimal but comparable to CTP-DWI. Nevertheless, DLNCCT-derived average lesion density and hypodense volume were associated with functional outcomes. KEY POINTS: Question Deep-learning models segment ischemic tissue on NCCT, but their spatial overlap and accuracy of imaging biomarker assessment relative to DWI and CTP core remain unclear. Findings Deep-learning NCCT segmentation showed good agreement with DWI in measuring hypodense (≤ 26 HU) volumes (- 4 mL [95% CI: -31; 23]; CCC 0.75). Clinical relevance Despite limited spatial overlap, NCCT-derived deep learning biomarkers showed agreement comparable to DWI, with improved performance in patients with poor ASPECTS and collateral scores. Hypodense volume and average lesion density were associated with functional outcome.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Deep learning-based segmentation of the ischemic core and severe hypodensity on noncontrast head CT compared with CT perfusion and diffusion-weighted imaging — Science Skim