European radiology

Transient flow modulation with rapid-resorbable gelatin microspheres during Yttrium-90 radioembolization for liver cancer: a preliminary clinical trial.

Jin Woo Choi, Minseok Suh, Jae Hyun Kim, Do Hoon Kim, Myungsu Lee, Saebeom Hur, Min Uk Kim, Hyo-Cheol Kim,

Department of Radiology, Seoul National University Hospital, Seoul, Korea. jwchoi.med@snu.ac.kr. · Department of Nuclear Medicine, Seoul National University Hospital, Seoul, Korea.

Trial · Phase II

Key points

From the paper's conclusion
  • RGM-mediated flow modulation was associated with reduced Y-90 microsphere deposition in the NTL, with imaging findings suggesting regional liver function preservation. This protective effect appeared greater with lower Y-90 microsphere load.

Abstract

OBJECTIVES: To explore the effectiveness of rapid-resorbable gelatin microspheres (RGMs) for protecting non-tumorous liver (NTL) through flow modulation during yttrium-90 (Y-90) radioembolization for liver cancer. MATERIALS AND METHODS: This phase II trial defined the primary outcome as the protection rate of RGM-embolized vs non-embolized NTL on Y-90 PET/CT. RGMs (560-800 µm) were used to transiently diminish blood flow to the NTL, followed by Y-90 microsphere administration. The effectiveness of flow modulation and radioembolization was assessed using Y-90 PET/CT and gadoxetic acid-enhanced MRI (EOB-MRI). RESULTS: Twenty patients were enrolled between March 2023 and January 2025. The median protection rate was 35.8% (interquartile range [IQR], 20.2-66.7). Seven patients (35%, 7/20) demonstrated a ≥ 2-fold increase in the tumor-to-NTL uptake ratio on Y-90 PET/CT compared with pre-treatment SPECT/CT. The signal intensity (SI) ratio between protected and unprotected NTLs on the hepatobiliary phase of EOB-MRI increased significantly from baseline (median, 1.03; IQR, 0.97-1.05) to 6-month follow-up (median, 1.29; IQR, 1.18-1.54; p < 0.001). The Y-90 microsphere load to the NTL was negatively correlated with the protection rate (ρ = -0.578, p = 0.010), whereas the protection rate was positively correlated with the SI ratio at 6 months (ρ = 0.710, p = 0.001). All patients who underwent subsequent intra-arterial treatments achieved complete arterial recanalization. CONCLUSION: RGM-mediated flow modulation was associated with reduced Y-90 microsphere deposition in the NTL, with imaging findings suggesting regional liver function preservation. This protective effect appeared greater with lower Y-90 microsphere load. KEY POINTS: Question Can flow modulation using RGMS preserve regional liver function? Findings Prior embolization with rapidly resorbable gelatin microspheres reduced the absorbed dose to the NTL by 35.8% and preserved signal intensity on EOB-MRI after radioembolization. Clinical relevance RGMs can transiently divert arterial flow away from the NTL, reducing Yttrium-90 microsphere influx and helping preserve regional liver function during Yttrium-90 radioembolization for liver cancer.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers