MRI for the detection of hip abductor tendon tears in symptomatic patients with total hip arthroplasty following a lateral surgical approach.
Adrian A Marth, Matthew Allen, Yuan Liu, Gabby B Joseph, Stefano A Bini, Thomas M Link, Georg C Feuerriegel
Department of Radiology, Balgrist University Hospital, Zurich, Switzerland. adrian.marth@balgrist.ch. · Department of Orthopaedic Surgery, University of California San Francisco, San Francisco, CA, USA.
Key points
From the paper's conclusion- MRI demonstrated high diagnostic accuracy for detecting surgically confirmed hip abductor tendon tears in this selected symptomatic surgical cohort following total hip arthroplasty. Tendon defects and peritrochanteric fluid were significantly associated with partial- or full-thickness tendon tears.
Abstract
OBJECTIVES: To evaluate the diagnostic accuracy of MRI for detecting clinically suspected hip abductor tendon tears in symptomatic patients after total hip arthroplasty and to evaluate the association between specific MRI features and surgically confirmed tears. MATERIALS AND METHODS: This retrospective study included 36 patients with total hip arthroplasty who underwent revision surgery for a suspected abductor tendon tear and had preoperative MRI available. Intraoperative findings served as the reference standard for the presence of partial or full-thickness tears of the gluteus medius (Gmed) and gluteus minimus (Gmin) tendons. Two readers evaluated MRI for tendon integrity (intact, partial-thickness, or full-thickness tear). Associations between tendon defects, peritrochanteric fluid, tendon signal abnormalities, and Gmed/Gmin Goutallier grades with surgical findings were analyzed using regression models to calculate odds ratios (ORs). RESULTS: For detection of abductor tendon tears, Reader 1 achieved sensitivities of 0.86-1.00, specificities of 0.93-1.00, and accuracies of 0.92-0.97, while Reader 2 achieved sensitivities of 0.86-1.00, specificities of 0.90-1.00, and accuracies of 0.89-1.00. Imaging findings associated with partial- or full-thickness tears included tendon defects (Gmed: OR = 35.5, p = 0.007; Gmin: OR = 30.0, p < 0.001), peritrochanteric fluid (Gmed: OR = 64.2, p = 0.01; Gmin: OR = 74.9, p = 0.01), and higher Goutallier grade (Gmed: OR = 2.34, p = 0.03; Gmin: OR = 4.75, p = 0.02). CONCLUSION: MRI demonstrated high diagnostic accuracy for detecting surgically confirmed hip abductor tendon tears in this selected symptomatic surgical cohort following total hip arthroplasty. Tendon defects and peritrochanteric fluid were significantly associated with partial- or full-thickness tendon tears. KEY POINTS: Question There is limited data on the diagnostic accuracy of MRI for hip abductor tendon tear detection following total hip arthroplasty. Findings MRI demonstrated high diagnostic accuracy for detecting surgically confirmed abductor tendon tears in symptomatic patients with total hip arthroplasty. Clinical relevance In symptomatic patients with clinical suspicion of an abductor tendon tear undergoing evaluation for revision surgery, MRI can be used to noninvasively assess the integrity of the abductor tendons after total hip arthroplasty.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP8.95 Hip Abductor Pathology and Postoperative Outcomes: Clinical Validation of the Wisconsin Hip Abductor (WHAb) Classification SystemJournal of Hip Preservation Surgery · 2026
- TP7.3 Ultrasonography as an Effective First-Line Imaging Modality for Hip Abductor Tendon Pathology: A Retrospective MRI Concordance StudyJournal of Hip Preservation Surgery · 2026
- EP7.12 Comparative Analysis of Open and Endoscopic Hip Abductor Tendon Repair: Findings from the HipSTR Multicenter DatabaseJournal of Hip Preservation Surgery · 2026
- Improved Outcomes in Hip Abductor Tendon Repairs With Augmentation and Gluteus Maximus Transfer: A Systematic Review.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- EP7.17 Hip Abductor Reconstruction with Human Dermal Allograft Shows Promising Outcomes and Increased Tendon Thickness at Short-Term Follow-UpJournal of Hip Preservation Surgery · 2026
- Diagnostic Accuracy of Magnetic Resonance Imaging Signs for Detecting Meniscal Root Tears: A Prospective Comparison with Arthroscopic Findings.Journal of orthopaedic case reports · 2026