Impact of AI assistance on reading time, cancer detection rate, and abnormal interpretation rate in screening and diagnostic mammography: a prospective alternating-month study.
Si Eun Lee, Seok-Jae Heo, Hyun Joo Shin, Eun-Kyung Kim
Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin-si, Republic of Korea. · Biostatistics Collaboration Unit, Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- AI assistance in routine mammography interpretation was not associated with prolonged reading time and was associated with a higher overall CDR.
Abstract
OBJECTIVE: To compare reading time, cancer detection rate (CDR), and abnormal interpretation rate (AIR) between AI-assisted and non-AI-assisted periods in screening and diagnostic mammography performed in routine clinical practice. MATERIALS AND METHODS: We prospectively collected reading times for consecutive two-view full-field digital mammography interpreted by four radiologists between August 2023 and July 2024. Both screening and diagnostic examinations were included. A commercially available AI system was integrated into the clinical workflow, with results displayed or hidden on a monthly basis. Reading time, CDR, and AIR were compared between two periods. For reading time analysis, a subset of 2917 examinations with times ≤ 5 min was included to minimize the impact of non-interpretive interruptions. Reading time was extracted from the PACS log. RESULTS: Among 4577 mammography examinations (mean age 51.7 ± 10.4 years), the overall CDR was higher during the AI-assisted period (22.3 vs 11.5 per 1000; p = 0.005). AIR did not differ for screening mammography (9.5% vs 8.4%; p = 0.293) but was higher with AI assistance for diagnostic mammography (18.7% vs 12.1%; p = 0.026). Mean reading times were comparable between AI-assisted and non-AI-assisted periods (65.0 vs 64.3 s; p = 0.723). CONCLUSION: AI assistance in routine mammography interpretation was not associated with prolonged reading time and was associated with a higher overall CDR. KEY POINTS: Question Does artificial intelligence assistance in routine mammography affect radiologists' reading time, cancer detection, or abnormal interpretation in daily practice? Findings Artificial intelligence assistance was not associated with prolonged reading time and was associated with a higher overall cancer detection rate. Abnormal interpretation increased only for diagnostic examinations, with no difference in screening examinations. Clinical relevance AI assistance may support screening mammography by aiding cancer detection without disrupting workflow, whereas diagnostic use should be applied carefully due to higher abnormal interpretation rates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI-based triage and decision support in mammography and digital tomosynthesis for breast cancer screening: a paired, noninferiority trialNature Medicine · 2026
- AI-integrated versus Standard Mammography Screening Pathways: A Systematic Review and Network Meta-Analysis of Diagnostic Accuracy.Radiology. Imaging cancer · 2026
- Diagnostic performance of FDA-cleared and CE-marked AI systems for mammography screening: a systematic review and meta-analysis.European journal of radiology · 2026
- Multicenter AI- versus expert-assisted RECIST target lesion measurements in follow-up body CT of patients with cancer.Radiology advances · 2026
- Artificial intelligence-supported double reading in European population breast cancer screening: A systematic review and meta-analysis of prospective programs.Clinical imaging · 2026
- Artificial Intelligence-Assisted Chest Radiography: A Prospective Crossover Multi-Reader Study on Diagnostic Performance and Workflow Efficiency.Academic radiology · 2026