Surgical and radiologic anatomy : SRA

Central corneal endothelial morphometry in emmetropic adults aged 20-40 years examined in Valencia, Spain: a retrospective cross-sectional analysis.

Juan A Sanchis-Gimeno, Josepha Hernandez-Nilo, Jessica Paola Loaiza-Giraldo, Nikolaos Lazaridis, George Triantafyllou, Maria Piagkou, Juan José Valenzuela-Fuenzalida

GIAVAL Research Group, Department of Anatomy and Human Embryology, Faculty of Medicine, University of Valencia, 46001, Valencia, Spain. juan.sanchis@uv.es. · Departamento de Morfología, Facultad de Medicina, Universidad Andrés Bello, Santiago, Chile.

Observational · n=202

Key points

From the paper's conclusion
  • These device- and sample-specific data provide an anatomical comparator for future studies but are not formal clinical reference intervals or surgical thresholds.

Abstract

PURPOSE: To provide a descriptive anatomical baseline for central corneal endothelial morphometry and examine cross-sectional associations with recorded sex and age in emmetropic adults examined in Valencia, Spain. METHODS: This retrospective cross-sectional secondary analysis included 202 de-identified records from adults aged 20-40 years. The historical research program operated from 2002 to 2012; exact participant-level examination dates were unavailable. Emmetropia required a spherical equivalent from -0.50 to +0.50 D, manifest sphere and cylinder within ±0.50 D, and best-corrected visual acuity of 20/20 or better. We obtained endothelial cell density (ECD), coefficient of variation of cell area (CV), percentage of hexagonal cells (%HEX), and mean cell area (MCA) using Topcon SP-2000P non-contact specular microscopy. We used Welch tests, Hedges' g, and false-discovery-rate correction for sex comparisons; age-adjusted models used HC3 robust standard errors with diagnostic and sensitivity analyses. RESULTS: The sample comprised 106 men and 96 women. Overall values were ECD 2908.1 ± 277.5 cells/mm2, CV 32.6 ± 3.7%, %HEX 59.9 ± 6.4%, and MCA 350.2 ± 35.0 µm2. No endpoint showed a detectable sex association after multiplicity control or age adjustment. Age was cross-sectionally associated with lower ECD, larger MCA, and modestly lower %HEX, although the %HEX association attenuated in sensitivity analyses. ECD and MCA were strongly inversely correlated (r = -0.803). CONCLUSION: These device- and sample-specific data provide an anatomical comparator for future studies but are not formal clinical reference intervals or surgical thresholds.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers