Division of Interventional Radiology, Department of Radiology, Keck School of Medicine of the University of Southern California, 1500 San Pablo Street, Los Angeles, CA, 90033, USA. eric.cyphers@med.usc.edu. · Division of Interventional Radiology, Department of Radiology, Keck School of Medicine of the University of Southern California, 1500 San Pablo Street, Los Angeles, CA, 90033, USA.
Key points
From the paper's conclusion- TIPS creation using the 6-10 mm device is a technically feasible strategy with adequate short-term hemodynamic response.
Abstract
PURPOSE: To evaluate the technical feasibility, hemodynamic effects, and early clinical outcomes of the 6-10 mm GORE VIATORR TIPS Endoprosthesis with Controlled Expansion, which extends the prior 8 mm deployment floor to 6 mm. MATERIALS AND METHODS: This single-center retrospective study included consecutive patients who underwent de novo transjugular intrahepatic portosystemic shunt (TIPS) creation with the 6-10 mm device between April and July 2026. Technical success was defined as portosystemic pressure gradient (PSPG) below 12 mmHg or ≥ 50% reduction from baseline. RESULT: Twelve patients (8 females, 4 males; mean age 57.1 ± 15.7 years; range 32-83 years) were included. Indications for TIPS creation were variceal hemorrhage (50.0%; n = 6/12), refractory ascites (33.3%; n = 4/12), and refractory hepatic hydrothorax (16.7%; n = 2/12). Final stent diameter was less than 8 mm in 91.7% (n = 11/12) of patients. Technical success was achieved in all patients, with mean PSPG decreasing from 16.7 ± 7.7 to 7.7 ± 2.9 mmHg (P < .001) and no immediate adverse events. Shunt patency was 100% at short imaging follow-up (mean, 35.6 ± 25.0 days), with no reinterventions. No recurrent variceal hemorrhage occurred, and ascites improved or resolved in 77.8% (n = 7/9) of patients at short clinical follow-up (mean, 50.5 ± 23.3 days). Four of 11 patients (36.4%) experienced symptomatic HE after TIPS creation and one patient (9.1%) died during the follow-up period. CONCLUSION: TIPS creation using the 6-10 mm device is a technically feasible strategy with adequate short-term hemodynamic response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prevention of Portal Hypertension Complications Beyond Primary TIPS Indication Is Independent of Endoprosthesis Under‐DilationLiver International · 2026
- Transjugular intrahepatic portosystemic shunt with ePTFE-covered stentgrafts: incidence and predictors of shunt dysfunctionInsights into Imaging · 2025
- Passive Stent Expansion as a Confounder in Under‐Dilated TIPS OutcomesLiver International · 2026
- Shunt magnitude is a key determinant of overt hepatic encephalopathy in patients undergoing TIPSJHEP Reports · 2025
- Comparison of underdilated versus standard transjugular intrahepatic portosystemic shunt in preventing rebleeding from oesophagogastric varices in patients with cirrhosis in Chinese tertiary hospitals: protocol for a multicentre randomised controlled trial (UVR-TIPS trial).BMJ open · 2026
- Predictive target of portal pressure reduction and clinical significance of the portal vein thrombosis subgroup for hepatic encephalopathy after TIPS in decompensated cirrhosis.Translational gastroenterology and hepatology · 2026